Uninterruptible Power Supply (UPS)

UPS-IND HF 1300

Uninterruptible Power Supply (UPS)

UPS-IND HF 1300

10~30 kVA
Voltage
+/-1%
Voltage regulation
2 Year Warranty

High Frequency On Line Double Conversion UPS is the most complete solution for protecting critical loads, allowing the user continuous operation and clean, regulated voltage.

  • On Line Double Conversion
  • Power Factor Correction
  • Parallelable Technology
  • Smart Ventilation Control
  • DSP Control
  • IGBT Technology
  • Maintenance Bypass
  • Electronic Bypass
  • EPO Function

Uninterrupted Power

Icono rayo
On Line Double Conversion
Guarantees clean and stable voltage output despite irregularities on the input.
Icono rayo
Power Factor Correction
Reduces gap between voltage and current for higher efficiency and functionality.
Icono rayo
Battery Back Up
Standard 5 Minute continuous power back up.
Icono rayo
Parallelable Technology
Parallel by capacity or redundancy n + 1 (master-slave exempt).
Icono rayo
Smart Ventilation Control
Automatic vent adapts speed in proportion to variations in demand or room temperature.
Icono rayo
DSP Control
Digital Signal Processor sustains high precision control and speed for optimal system performance.
Icono rayo
IGBT Technology
High efficiency and fast switching controller that adapts to high power applications.
Icono rayo
SNMP Network Card
Monitoring equipment alerts, controls and tracks current status of UPS from any off site location.
Icono rayo
Maintenance Bypass
Bypass switch enables safe UPS electrical isolation during maintenance or testing.
Icono rayo
Electronic Bypass
Automatic bypass ensures operational continuity in the event of a failure.

Applications

Commercial buildings
Commercial buildings
Computer Rooms
Computer Rooms
Data Centers
Data Centers
Lab equipment
Lab equipment
Medical Equipment
Medical Equipment
Office
Office
Precision Instruments
Precision Instruments
Regional Office Building
Regional Office Building

Technical Specifications

UPS-IND HF
1310
1315
1320
1330
Capacity (kVA / kW) 10/9 15/13.5 2/18 30/27
Input Voltage (V) 127 / 220
Overload Protection Thermomagnetic switch & bypass
Range (Accepted) – 15 %, + 20 %
Phases Star 3 Phase (4 wires + ground)
Frequency 50 / 60 ± 10 %
Power Factor > 0.99
Input Efficiency ≥ 93%
UPS-IND HF
1310
1315
1320
1330
Overload Protection Thermomagnetic switch on the output
Output Power Factor 0.9
Voltage (Vca) 127 / 220 or 120 / 208
Voltage Regulation Range ± 1% (typical)
Frequency (Hz) 50 / 60 ± 0.01%
Wave Form THD pure sinusoidal wave ≤ 1% (linear load), ≤ 3% (non-linear load)
Transfer Time (ms) 0.0 (on line)
Connection Type Star (3 phases, 4 wires + ground)
Overload 125% of nominal load for 10 min.; 150% for 1 min.
UPS-IND HF
1310
1315
1320
1330
Voltage (Vcd) 192
Battery Type Lead acid (sealed, maintenance free)/ (optional: nickel cadmium)
Battery Backup Time at Full Load (min) 8 – 25 5 – 15 5 – 10 5 (15 external)
Maximum Load Current (A) 6
Battery Bank Internal / (optional: external for extended backup time)
UPS-IND HF
1310
1315
1320
1330
Audible Noise (dB) < 65, to 1 meter
MTBF (h) 233,000
Operational Temperature (°C) 0~40
Relative Humidity 0 ~ 95% without condensation
Maximum Operating Altitude (mamsl) 2,000 at 100% & 3,000 at 96%
Cooling Type Forced air
Cabinet Electrostatic baked epoxy coated steel, grade IP20 or NEMA 1
Dimensions, height x width x depth (mm) 1500 x 500 x 8000 1650 x 500 x 800
Weight (kg) 460 / (380 w/o batteries) 480 / (400 w/o batteries)

Battery StatusReal time Online/Discharge information with 3% precision

UPS-IND HF
1310
1315
1320
1330
Conversion Type On-line double conversion (online)
Rectifier IGBT Technology
Inverter Conmutation Elements PWM Pulse width modulation technology w/ conmuted IGBT
Thermal Dissipation (kBTU/h) 1.7 2.6 3.6 5.4
Internal Bypass Two: electronic (automatic) bypass, and manual bypass for maintenance/repair
Paralleling n+1 up to 4 units
Certifications CE-IEC 62040 -1, ISO 9001:2015
Communication Interface RS485, dry contact relay signal, SNMP network card included
or MODBUS ethernet w/ one port per unit & 2 ports in parallel
LCD Monochromatic Screen BBacklight: Input/Output voltage, load capacity, battery voltage, operating status
Alarm Overload, abnormal alternate current on the input, low battery
Protection Low battery, overheating, short circuit, over/low voltage on output

Power Calculator

Instantly calculate equipment capacity by filling in the missing information: