Industrial grade performance, top tier precision.
Redundancy and 100% reliability.
AMCR
|
23300
|
23400
|
23500
|
---|---|---|---|
Capacity (kVA / kW) | 300/300 | 400/400 | 500/500 |
Input Voltage (V) | 110/190, 115/200, 120/208, 127/220 or 254/440, 266/460, 277/480 | ||
Overload Protection | Thermo-magnetic switch | ||
Range (Accepted) | ± 15% | ||
Operational Frequency | 60 ± 10%, does not alter frequency* | ||
Harmonic Distortion | Less than 2 % THD | ||
Power Factor | Does NOT alter, adaptable to load requirement |
* Tolerance available under evaluation of the Engineering department
AMCR
|
23300
|
23400
|
23500
|
---|---|---|---|
Voltage Regulation Range | ± 2% (typical) | ||
Output Voltage (V) | 110/190, 115/200, 120/208, 127/220 or 254/440, 266/460, 277/480 | ||
Power Supply Impedance | Less than 2% | ||
Sustained High/Low Voltage Protection | Contactor or relay on the output, automatic shut off (varies by model) | ||
Correction Time | Immediate, (8.3 milliseconds, 1/2 cycle) | ||
Reset | Automatic (programmed at factory) | ||
Reset Time | 3 second standard time ** |
** Factory configurable on request
AMCR
|
23300
|
23400
|
23500
|
||
---|---|---|---|---|---|
Recommended Use | Domestic, commercial and/or industrial, non vibratory, indoor use | ||||
Transformers | Electrolytic copper magnetic wire and silicon steel sheet | ||||
Cooling & Ventilation | Natural convection | ||||
Cabinet | Galvanized steel sheet with tubular steel frame | ||||
Paint Finish | Primer and electrostatic baked epoxy powder coating or air-dry (varies by model) | ||||
Maximum Altitude Of Operation (mamsl) | 3,000 | ||||
Operational Temperature (°C) | 0 ~ 40 | ||||
Relative Humidity | 0 ~ 95% without condensation | ||||
Dimensions, height x width x depth (mm) | 1575 x 1570 x 802 | 2360 x 2290 x 1330 | |||
Weight (kg) | 892 | 1052 | 1672 |
AMCR
|
23300
|
23400
|
23500
|
---|---|---|---|
High Frequency Noise Protection | PI Filter | ||
Control Technology | Microcontroller | ||
Monitoring (Operational Status) | Display with LEDs / Ethernet (optional) | ||
Measurement Parameters | Voltage, current, power, frequency, power factor | ||
Electronic Commutation | TRIACs or SCRs (varies by model) |
AMCR
|
23300
|
23400
|
23500
|
---|---|---|---|
Regulation | Line-Line & Line-Neutral | ||
Spike Suppressor | Varistors on the output | ||
Efficiency | 98% minimum | ||
Overload Capacity | Up to 400% in intermittent startups |
AMCR
|
23800
|
231000
|
---|---|---|
Capacity (kVA / kW) | 800/800 | 1000/1000 |
Input Voltage (V) | 110/190, 115/200, 120/208, 127/220 or 254/440, 266/460, 277/480 | |
Overload Protection | Thermo-magnetic switch | |
Range (Accepted) | ± 15% | |
Operational Frequency | 60 ± 10%, does not alter frequency* | |
Harmonic Distortion | Less than 2 % THD | |
Power Factor | Does NOT alter, adaptable to load requirement |
* Tolerance available under evaluation of the Engineering department
AMCR
|
23800
|
231000
|
---|---|---|
Voltage Regulation Range | ± 2% (typical) | |
Output Voltage (V) | 110/190, 115/200, 120/208, 127/220 or 254/440, 266/460, 277/480 | |
Power Supply Impedance | Less than 2% | |
Sustained High/Low Voltage Protection | Contactor or relay on the output, automatic shut off (varies by model) | |
Correction Time | Immediate, (8.3 milliseconds, 1/2 cycle) | |
Reset | Automatic (programmed at factory) | |
Reset Time | 3 second standard time ** |
** Factory configurable on request
AMCR
|
23800
|
231000
|
---|---|---|
Recommended Use | Domestic, commercial and/or industrial, non vibratory, indoor use | |
Transformers | Electrolytic copper magnetic wire and silicon steel sheet | |
Cooling & Ventilation | Natural convection | |
Cabinet | Galvanized steel sheet with tubular steel frame | |
Paint Finish | Primer and electrostatic baked epoxy powder coating or air-dry (varies by model) | |
Maximum Altitude Of Operation (mamsl) | 3,000 | |
Operational Temperature (°C) | 0 ~ 40 | |
Relative Humidity | 0 ~ 95% without condensation | |
Dimensions, height x width x depth (mm) | 2600 x 2500 x 1500 | |
Weight (kg) | 2100 | 3000 |
AMCR
|
23800
|
231000
|
---|---|---|
High Frequency Noise Protection | PI Filter | |
Control Technology | Microcontroller | |
Monitoring (Operational Status) | Display with LEDs / Ethernet (optional) | |
Measurement Parameters | Voltage, current, power, frequency, power factor | |
Electronic Commutation | TRIACs or SCRs (varies by model) |
AMCR
|
23800
|
231000
|
---|---|---|
Regulation | Line-Line & Line-Neutral | |
Spike Suppressor | Varistors on the output | |
Efficiency | 98% minimum | |
Overload Capacity | Up to 400% in intermittent startups |