UPS-IND 5100

Uninterruptible Power Supply (UPS)
UPS interactivo Industronic

UPS-IND 5100

Uninterruptible Power Supply (UPS)
1500 VA
Capacity
2 Year Warranty
Manufactured in Mexico

The Single-Phase Interactive UPS protects your home computers, security systems and routers against power outages. Its LCD display facilitates control and its batteries are easily replaced.

  • Interactive UPS
  • BOOST type voltage regulator
  • Integral LCD display
  • Surge protection
  • Easy battery replacement
  • Cold start for 120 Vac models

Features

Icono rayo
Interactive UPS
Provides electrical backup and automatic voltage regulation for sensitive equipment.
Icono rayo
BOOST type voltage regulator
Stabilizes the voltage in case of fluctuations without using the battery.
Icono rayo
Integral LCD display
Displays real-time UPS status and operating parameters.
Icono rayo
Surge protection
Maintains stable power supply and prevents damage from voltage spikes.
Icono rayo
Easy battery replacement
Allows quick maintenance without affecting operation.
Icono rayo
Cold start
Starts the UPS without connection to the mains in case of emergency.

Learn more in our blog

Learn the differences between UPS Interactive vs. UPS Online

ups interactivo

Read now

Applications

Technical Specifications

5110 I1 5115 I1
Capacity (VA/W) 1000 VA/600W 1500 VA/900W
Overload protection Thermomagnetic switch
Voltage (Vca) 110, 120 Vca
Accepted voltage range 81-132, 86-142 Vca
Phases 1 phase + neutral + ground
Frequency (Hz) 50/60 Hz (automatic selection)
Maximum input current 12 A 18 A
5110 I1 5115 I1
Output power factor 0,6
Voltage (Vca) 110, 120 Vca
Battery voltage regulation range ±5%
Frequency (Hz) 50/60 Hz ±1Hz
Waveform Simulated sinusoidal
Transfer time (ms) 6ms typical, 10 ms maximum
Maximum output current 5 7,5
5110 I1 5115 I1
Voltage (Vcd) 12 V/ 9 Ah X 1 12 V/ 9 Ah X 2
Battery type Lead acid (sealed and maintenance-free)
Backup time (min) 1 PC(200W) 6 minutes 1 PC(200W) 30 minutes, 2 PC (400W) 10 minutes
Batteries Internal
Battery recharge time 6 to 8 hours (90% recovery)
Service life 3 to 5 years at 25ºC. At higher temperatures, the service life is considerably reduced. To keep the batteries healthy, we recommend recharging them at least once every 3 months and, to prevent damage, recharging them every 6 months
5110 I1 5115 I1
Input connection 1 NEMA 5-15P
Output connection 5 NEMA 5-15R Backed, 5 NEMA 5-15R Surge Protected
Audible noise (dB) Less than 40 dB at one meter Less than 45 dB at one meter
Operating temperature (°C) 0-40 °C
Relative humidity 0-90 %
Maximum operating altitude (m.a.s.l.) 2000 masl
Dimensions, height x width x depth (mm) 280 x 99 x 288 280 x 99 410
UPS weight (kg) 8,5 12
5110 I1 5115 I1
LCD display Input and output voltage, input and output frequency, load level in VA, load level in watts, battery capacity, estimated remaining operating time
Alarms 5110 I1 5115 I1
Battery mode Sound every 10 seconds
Low battery Sound every second
Overload Sound every half second
Failure Continuous sound
Protection Output discharge, overload, and short-circuit protection
Certifications NOM

Request quote

    Power Calculator

    Instantly calculate equipment capacity by filling in the missing information:

    Whatsapp Whatsapp