UPS-IND HF 1300 M1 (40-200)

Uninterruptible Power Supply (UPS)
UPS-IND HF 1300 M1

UPS-IND HF 1300 M1 (40-200)

Uninterruptible Power Supply (UPS)
40 ~ 200 kVA
Capacity
+/- 1%
Voltage regulation
2 Year Warranty

The high frequency UPS-IND HF 1300 M1 provides power backup solutions for critical loads, thanks to its three-level inverter with PWM type IGBT technology provides adaptive management to higher powers, operating at high speed and higher efficiency.

  • On-line double conversion
  •  1.0 Power Factor
  • High Efficiency of 97%
  • Lower Footprint
  • Dual DSP for high reliability and performance
  • 2 Optional slot for SNMP and dry contact
  • 3 Level IGBT Technology Inverter
  • Dual input power supply: Mains and bypass
  • Anti-corrosion resistant coating for all PCB boards
Certificaciones

Garantías

Manuales y Guías Rápidas

Features

Icono rayo
On Line Double Conversion
Guarantees clean and stable voltage output despite irregularities on the input.
Icono rayo
1.0 Power Factor
The 1.0 power factor ensures efficiency and performance, optimizing the electrical system
Icono rayo
Dual DSP
Dual Digital Signal Processor (DSP) high precision and high speed control for maximum system performance.
Icono rayo
High Efficiency
AC/AC efficiency up to 97%
Icono rayo
3 Level IGBT
3 Level IGBT Technology Inverter
Icono rayo
Doble Bypass
Automatic bypass ensures continuity of power to connected devices even in the event of equipment failure.
Icono rayo
ECO-IND Mode
99% efficiency in ECO mode (when bypass voltage and frequency are within the permitted range).
Icono rayo
Anti-corrosion PCB boards
Anti-corrosion resistant coating for all PCB boards
Icono rayo
Parallelable Technology
Parallel by capacity N + 1 or redundancy N+X+1 (Up to 8)

Video

Applications

Technical Specifications

Modelo: UPS-IND HF
1340 M1
1360 M1
1380 M1
13100 M1
13120 M1
13160 M1
13200 M1
Capacity (kW/ kVA)2 40/40 60/60 80/80 100/100 120/120 160/160 200/200
Voltage(Vca)

120/208, 127/220,  220/380, 230/400, 254/440, 266/460, 277/480

Overload Protection Thermal magnetic input circuit breaker and Thermal magnetic bypass circuit breaker
Voltage Range (Vac) +/- 20% (Line to Line)
Phase Three Phase Star, 3 Phases + Neutral + Ground, optional: Delta (3 Phases + Ground)
Frequency Range (Hz) 40 ~ 70
Input Power Factor

≥ 0.99 at full load

THDi ≤ 3%

 

Modelo: UPS-IND HF
1340 M1
1360 M1
1380 M1
13100 M1
13120 M1
13160 M1
13200 M1
AC to AC Maximum Efficiency 97 %
Overload Protection Thermal magnetic output circuit breaker
Output Power Factor 1.0
Voltage (Vac)

120/208, 127/220,  220/380, 230/400, 254/440, 266/460, 277/480

Voltage Regulation Range (Vac) +/- 1 %
Frequency (Hz) 60 +/- 0.1% (battery mode) (optional: 50 Hz)
Waveform Pure sinoidal wave
Harmonic Distortion THDv ≤ 1% (carga lineal), ≤ 4% (non linear load)
Transfer Time (ms) 0.0 milisegundos (true on line)
Connection Type Three phase star, 3 phases + neutral + ground, optional: delta (3 phases + ground)3
Overload

101 a 105% continuous, 106 a 110% 60 min, 111 a 125% 10 minutos,126 a 150% 60 segundos, > 150% immediate switch to bypass

Modelo: UPS-IND HF
1340 M1
1360 M1
1380 M1
1300 M1
13120 M1
13160 M1
13200 M1
Voltage (Vcd) +/-192 (+/-168 a +/- 288 adjustable)
Full load backup time (min) 5 standard (extended time available upon request)
Battery Type Lead Acid (Sealed & Maintenance Free)
Maximum Load Current (A) 30 60
Banco de baterías Internal External

 

Physical & Mechanical 1340 M1 1360 M1 1380 M1 13100 M1 13120 M1 13160 M1 13200 M1
Audible Noise (db) < 65 at 1 meter
Operating Temperature (ºC) 0 to 40
Relative Humidity 0 – 95% without condensation
Maximum Operating Altitude (m.a.s.l.) 2400 at 100%, 3000 at 96%
Cabinet Baked electrostatic Epoxy coated steel
Dimensions x height x width x depth (mm) 1600 x 950 x 1000 1800 x 1100 x 1220
UPS net weight (kg) 480 720 960 1100 1200 1460 1610
Modelo: UPS-IND HF 1340 M1 1360 M1 1380 M1 1300 M1 13120 M1 13160 M1 13200 M1
Inverter level IGBT technology for higher efficiency and minimized interference to grid
Rectifier High Efficiency PFC type with IGBT technology
Output Isolation Transformer Optional
Battery Status Real Time Online/Discharge Information
Thermal Dissipation (kBTU / h) 4.1 6.1 8.2 10.2 12.3 16.4 20.5
Internal Bypass Two Bypass Modes: Automatic Static & Manual Bypass Switch for Maintenance
Paralleling Parallelable by Capacity and/or Redundancy N + 1 (up to 8 units)
Certifications CE-62040-1, CE 62040-2, ISO 9001:2015
Communications Interface RS485 + EPO, 5 dry contact output signals, 1 dry contact input, RS232, SNMP network card
Digital Touch Screen Displays: Input and output voltage, Load capacity, Battery voltage, Operating Status Mimic and LEDs Indicators
Alarms Low Battery, Abnormal Input, UPS Failure, etc.
Protection Low Battery, Overload, Short Circuit, Over Temperature, etc.