High Frequency, On Line, Double Conversion UPS is the most complete solution for protecting critical loads, allowing the user continuous operation and clean, regulated voltage.
|
UPS IND HF
|
13225 |
13300
|
13400
|
13500
|
13600
|
13225
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|---|---|---|---|---|---|
| Capacity (kW / kVA) | 225/225 | 300/300 | 400/400 | 500/500 | 600/600 | 225/ 225 | 300/300 | 400/400 | 500/500 | 600/600 |
| Voltage (Vca) | 120/208, 127/220 | 254/440, 266/460, 277/480 | ||||||||
| Overload Protection | Thermal magnetic input circuit breaker and Thermal magnetic bypass circuit breaker | |||||||||
| Online Voltage Range (Vca) | +/- 20% at 100% Load, +/- 25% at 75% Load, +/- 30% at 50% Load | |||||||||
| Phases | Three Phase Star, 3 Phases + Neutral + Ground | |||||||||
| Frequency(Hz) | 50/60 ± 10 % | |||||||||
| THDi | ≤ 2 % (at 100% Load); ≤ 4 % (at 50% Load) | |||||||||
| Input Power Factor | ≥ 0.99 | |||||||||
|
UPS IND HF
|
13225 |
13300
|
13400
|
13500
|
13600
|
13225
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|---|---|---|---|---|---|
| Overload Protection | Thermal magnetic output circuit breaker | |||||||||
| Output Power Factor | 1.0 | |||||||||
| Voltage (Vca) | 120/208, 127/220 | 254/440, 266/460, 277/480 | ||||||||
| Voltage Regulation Range | ± 1% | |||||||||
| Frequency(Hz) | 50/60 ± 0.1% (Battery Mode), 50/60 ± 1 ~5 (Online Mode) | |||||||||
| Wave Form | Pure Sinosoidal Wave, THD ≤ 1% (Linear Load); ‹ 3% (Nonlinear Load) | |||||||||
| Transfer Time (ms) | 0.0, True Online | |||||||||
| Connection Type | Star, 3 Phases + Neutral + Ground | |||||||||
| Overload | 110% 60 min; 125% 10 min; 150% 1 min | |||||||||
| Efficency | 97% | |||||||||
| Load Imbalance Capacity | 100% | |||||||||
|
UPS IND HF
|
13225 |
13300
|
13400
|
13500
|
13600
|
13225
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|---|---|---|---|---|---|
| Voltage (Vcd) | 384 – 528 Adjustable | |||||||||
| Battery Type | Lead Acid (Sealed & Maintenance Free) / (Optional Nickel Cadmium) | |||||||||
| Full load backup time (min) | 5 min Standard (Extended Time available upon request) | |||||||||
| Maximum Load Current (A) | 25 – 100 | 25 – 200 | 25 – 100 | 25 – 200 | ||||||
| Battery Bank | External Bank | |||||||||
|
UPS IND HF
|
13225 |
13300
|
13400
|
13500
|
13600
|
13225
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|---|---|---|---|---|---|
| Audible Noise (dB) | < 65, a 1 Meter | |||||||||
| MTBF (hrs) | 233,000 | |||||||||
| Operatingl Temperature Range (°C) | -5 ~ 40 | |||||||||
| Relative Humidity | 0 ~ 95% without Condensation | |||||||||
| Maximum Operating Altitude (mamsl) | 3,000 | |||||||||
| Finish | IP 20, Baked Electrostatic Epoxy Coated Steel | |||||||||
| Dimensions: height x width x depth (mm) | 1950 x 1800 x 900 | 1950 x 1800 x 1000 | 1950 x 2300 x 1200 | 1950 x 1650 x 900 | 1950 x 2150 x 900 | |||||
| UPS Weight (kg)** | 1850 | 2050 | 2250 | 2800 | 3100 | 1550 | 1650 | 1750 | 2200 | 2300 |
|
UPS IND HF
|
13225 |
13300
|
13400
|
13500
|
13600
|
13225
|
13300
|
13400
|
13500
|
13600
|
|---|---|---|---|---|---|---|---|---|---|---|
| Conversion Type | Online Double Conversion (True Online) | |||||||||
| Rectifier | IGBT type with High Power Factor | |||||||||
| Inverter Conmutation Elements | GBT with PWM Pulse Width Management Technology | |||||||||
| Filters | PFC to Reduce Harmonic Distortion (2% RMS) | |||||||||
| Battery Status | Real Time Online/Discharge Information with 3% Precision | |||||||||
| Thermal Dissipation (kBTU / h) | 23.5 | 31.7 | 42.3 | 52.9 | 63.5 | 23.5 | 31.7 | 42.3 | 52.0 | 63.5 |
| Internal Bypass | Two Bypass Modes: Automatic Static & Manual Bypass Switch for Maintenance | |||||||||
| Paralleling | Parallelable by Capacity and/or Redundancy N + 1 (up to 8 units) | |||||||||
| Certifications | CE-IEC 62040 -1, ISO 9001:2015, NOM | |||||||||
| Communication Interface | RS485 / SNMP/ Dry Contacts / MODBUS | |||||||||
| LCD Color Screen | Backlight: Input/Output Voltage, Load Capacity, Battery Voltage, Operation Status | |||||||||
| Alarm | Overload, Abnormal Input, Low Battery, Failure | |||||||||
| Protection | Output Short Circuit, Overload, Overheating, Battery Low Voltage, High/Low Output Voltage | |||||||||