High precision protection from dangerous electrical voltages and other common disturbances, providing extended life expectancy and providing clean, reliable uninterrupted power.
|
UPS-IND
|
1222
|
||
|---|---|---|---|
| Capacity (kVA / kW) | 3/2.4 | ||
| Input Voltage (V) | 220, 230, 240 | ||
| Overload Protection | Electronic breaker | ||
| Range (Accepted) | ± 25% (165 – 300) | ||
| Phases | 2 Phase + ground | ||
| Frequency | 50/60 +_ 10 % (autoadjustable) | ||
| Power Factor | 0.90 when empty > 0.95 at full load | ||
|
UPS-IND
|
1222
|
||
|---|---|---|---|
| Output Power Factor | 0.8 | ||
| Voltage (Vca) | 120-208-220-230-240 (only 120 and 220 available at the same time) | ||
| Voltage Regulation Range | ± 1% (typical) | ||
| Phases | 2 phases+ neutral + ground | ||
| Frequency (Hz) | 50 / 60 +_ 0.2% (battery mode) | ||
| Wave Form | THD Pure sinusoidal wave ≤ 3% (linear load) | ||
| Transference Time (ms) | 0.0 (on line) | ||
| Overload | 105% < load < 130% 60 s, 130% < load < 150% 1 s, > 150% 200 ms | ||
|
UPS-IND
|
1222
|
||
|---|---|---|---|
| Voltage (Vcd) | 96 | ||
| Battery Type | Lead acid (sealed and maintenance free) | ||
| Battery Backup Time at Full Load (min) | 5 (standar) | ||
| Maximum Load Current (A) | 1 (optional 4, adding charger) | ||
| Battery Bank | Internal (optional external for extended time) | ||
|
UPS-IND
|
1222
|
||
|---|---|---|---|
| Audible Noise (dB) | < 55, to 1 meter | ||
| MTBF (h) | 100,000 | ||
| Operational Temperature (°C) | -5~40 | ||
| Relative Humidity | 0 ~ 95% without condensation | ||
| Maximum Operating Altitude (mamsl) | 2,000 at 100% & 3,000 at 96% | ||
| Cabinet | Steel with electrostatic baked epoxy paint | ||
| Dimensions, height x width x depth (mm) | 350 x 200 x 670 | ||
| Weight (kg) | 46 | ||
|
UPS-IND
|
1222
|
||
|---|---|---|---|
| Conversion Type | On-line double conversion (online) | ||
| Rectifier | H bridge PFC rectifier | ||
| Inverter Conmutation Elements | PWM technology with IGBT conmuted at 9000 Hz | ||
| Inverter Configuration | Pulse width modulated (PWM) | ||
| Inverter Type | H bridge | ||
| Battery Status | Real time online and discharge data with 3% precision | ||
| Thermal Dissipation (kBTU/h) | 0.9 | ||
| Certifications | CE-IEC 62040 – 1, ISO 9001: 2015, NOM | ||
| Internal Bypass | Static | ||
| Communication Interface | RS232 (optional: SNMP ethernet network card) | ||
| Communication Interface | RS232 (optional: SNMP ethernet network card) | ||
| Emergency Power Outage (EPO) | Connection for external emergency stop | ||
| Monochromatic LCD Screen | Backlight: input/output voltage, load capacity, battery voltage, operating status | ||
| Alarm | Overload, abnormal alternate current on the input | ||