The Single-Phase Interactive UPS protects your home computers, security systems and routers against power outages. Its LCD display facilitates control and its batteries are easily replaced.
This I1 UPS integrates a BOOST voltage regulator that automatically corrects voltage drops without using the battery. When the input voltage drops below the appropriate level, the system raises the voltage to a safe range for the connected equipment. This prevents unexpected restarts and low voltage failures, while reserving the battery for total power outage events.
This model features protected power outlets that help mitigate voltage spikes caused by disturbances in the electrical grid. Events such as distant lightning strikes, power failures, or sudden reconnections can generate surges that can affect sensitive electronic equipment, so this feature acts as an additional safety barrier.
| 5115 I1 | |
| Capacity (VA/W) | 1500 VA/900W |
| Overload protection | Thermomagnetic switch |
| Voltage (Vca) | 120 Vca |
| Accepted voltage range | 86-142 Vca |
| Phases | 1 phase + neutral + ground |
| Frequency (Hz) | 60 Hz |
| Maximum input current | 18 A |
| 5115 I1 | |
| Output power factor | 0,6 |
| Voltage (Vca) | 120 Vca |
| Battery voltage regulation range | ±5% |
| Frequency (Hz) | 60 Hz ±1Hz |
| Waveform | Simulated sine wave |
| Transfer time (ms) | 6ms typical, 10 ms maximum |
| Maximum output current | 7,5 |
| 5115 I1 | |
| Voltage (Vcd) | 12 V/ 9 Ah X 2 |
| Battery type | Lead acid (sealed and maintenance-free) |
| Backup time (min) | 1 PC(200W) 30 minutes, 2 PC (400W) 10 minutes |
| Batteries | Internal |
| Battery recharge time | 6 to 8 hours (90% recovery) |
| Service life | 3 to 5 years at 25ºC. At higher temperatures, the service life is considerably reduced. To keep the batteries healthy, we recommend recharging them at least once every 3 months and, to prevent damage, recharging them every 6 months |
| 5115 I1 | |
| Input connection | 1 NEMA 5-15P |
| Output connection | 5 NEMA 5-15R Backed, 5 NEMA 5-15R Surge Protected |
| Audible noise (dB) | Less than 45 dB at one meter |
| Operating temperature (°C) | 0-40 °C |
| Relative humidity | 0-90 % |
| Maximum operating altitude (m.a.s.l.) | 2000 masl |
| Dimensions, height x width x depth (mm) | 280 x 99 x 410 |
| UPS weight (kg) | 12 |
| 5115 I1 | |
| LCD display | Input and output voltage, input and output frequency, load level in VA, load level in watts, battery capacity, estimated remaining operating time |
| Alarms | 5115 I1 |
| Battery mode | Sound every 10 seconds |
| Low battery | Sound every second |
| Overload | Sound every half second |
| Failure | Continuous sound |
| Protection | Output discharge, overload, and short-circuit protection |
| Certifications | NOM |
Instantly calculate equipment capacity by filling in the missing information: