UPS-IND MR1 1300: 20-140 kVA uninterruptible power supply                                       [](#)

 # UPS-IND MR1 1300

###### Uninterruptible Power Supply (UPS)

  ![](https://grupoindustronic.com/wp-content/uploads/2021/03/MR1-MAYO-2021.png)

  ![](https://grupoindustronic.com/wp-content/uploads/2021/03/MR1-MAYO-2021.png)

 ## UPS-IND MR1 1300

###### Uninterruptible Power Supply (UPS)

  ###### 20 ~ 140 kVA

 Capacity

###### +/- 1%

 Voltage regulation

  2 Year Warranty

Manufactured in Mexico

 The modular UPS has been specially designed for sites and data centers. DSP control provides an improved solution with top performance. Integrated with modular design and parallel technology, UPS-IND MR1 simplifies future power expansion

- On-line double conversion
- Power factor 1.0
- Additional slot for SNMP Network or Dry Contacts
- Dual Input Power Supply (Normal and Bypass)
- DSP Technology for High Performance and Reliability
- Scalability for Modules and Parallel Equipment
- Power Modules and Batteries designed for Hot Swapping
- Inverter with 3 level IGBT technology
- High Efficiency, up to 94%.

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ UPS-IND MR1 1300 (20 ~ 140 kVA) Datasheet ](https://grupoindustronic.com/wp-content/uploads/2021/03/Datasheet-MR1-20-140-1.pdf)

##   ![Manuales](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) User Manuals

- [ UPS-IND MR1 1300 (20 ~ 140 kVA) Handbook ](https://industronicservice.zendesk.com/hc/es-419/articles/4402394888467-Manual-UPS-IND-MR1-1320-UPS-IND-MR1-1340-UPS-IND-MR1-1340-UPS-IND-MR1-1360-UPS-IND-MR1-1380-UPS-IND-MR1-13100-UPS-IND-MR1-13120-UPS-IND-MR1-13140)

##   ![Garantías](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Warranties

- [ UPS-IND Warranty ](https://industronicservice.zendesk.com/hc/es-419/articles/36880833951123-UPS-IND-Warranty)

 Share: [Correo](mailto:?subject=UPS-IND%20MR1%201300&body=https://grupoindustronic.com/en/product/ups-mr1-1300/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/ups-mr1-1300/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/ups-mr1-1300/)

 #### Uninterrupted Power

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/Doble-conversio%CC%81n-en-li%CC%81nea.png)

###### On-line double conversion

Guarantees a clean and stable output voltage at all times, regardless of power supply variations.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/05/fp1.png)

###### Power factor 1.0

The 1.0 power factor ensures efficiency and performance, optimizing the electrical system.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/control-DSP.png)

###### DSP technology

Digital Signal Processor (DSP) high precision and fast control for maximum system performance.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/conexion-en-paralelo.png)

###### Scalability

4 or 8 Modules (depending on the model) for N+1 or N+ X in the same unit and 2 Units in parallel.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2021/01/3-niveles.png)

###### Inverter with 3 level IGBT

Management with IGBT technology adaptable to higher powers, operating at high speed and higher efficiency.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2021/01/94.png)

###### High Efficiency

Maximum AC to AC efficiency of 94%.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/planes-actualizados.png)

###### Hot Swap

Power Modules and Batteries designed for Hot Swapping.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2021/03/carcat-ups-mr.png)

###### Intelligent double slot

Additional slot for SNMP Network or Dry Contacts

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2021/01/dual-input.png)

###### Dual Input

Dual Input Power Supply (Normal and Bypass)

### Video

#### Applications

 ![Audiovisual Systems](https://grupoindustronic.com/wp-content/uploads/2020/04/audiovisual.png)

###### Audiovisual Systems

Ensure the operability of audiovisual equipment against electrical fluctuations.

 ![Banks](https://grupoindustronic.com/wp-content/uploads/2020/02/bancos.png)

###### Banks

Protect servers, terminals and banking transaction systems against power interruptions.

 ![Commercial buildings](https://grupoindustronic.com/wp-content/uploads/2020/04/centro-comer.png)

###### Commercial buildings

Protects HVAC systems, lighting and lifts from electrical fluctuations and power outages.

 ![Precision Instruments](https://grupoindustronic.com/wp-content/uploads/2020/02/maquinaria-herramienta-y-de-control-numerico.png)

###### Precision Instruments

Ensure accuracy of sensitive instruments against electrical fluctuations and harmonics.

 ![Regional Office Building](https://grupoindustronic.com/wp-content/uploads/2020/02/edificios-inteligentes.png)

###### Regional Office Building

Ensures the stability of critical systems and office equipment in the event of power outages.

 ![Telecommunication](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-equipo-de-telecomunicacion.png)

###### Telecommunication

Ensure the continuity of telecommunications services in the event of power surges.

  &gt;

 &lt;

#### Technical Specifications

 Input

 ModelUPS-IND MR1 1380 (80 kVA)

UPS-IND MR1 13140 (140 kVA)

Overload ProtectionThermal magnetic input circuit breaker and Thermal magnetic bypass circuit breakerVoltage Range (Vac)156 to 253 (Line to Line): -29 % , +15 %PhaseThree Phase Star, (3 Phases + Neutral + Ground), optional: Delta (3 Phases + Ground)Frequency Range (Hz)40 ~ 70Input Power Factor≥ 0.99 at full load, ≥ 0.98 at 50% of the loadPower Modules (20 kW)47+1THDi≤ 3% at full load

 Output

 ModelUPS-IND MR1 1380 (80 kVA)

UPS-IND MR1 13140 (140 kVA)

Capacity (W/ VA)80000/80000140000/140000AC to AC Maximum Efficiency94 % above 50 % loadOverload ProtectionThermal magnetic output circuit breakerOutput Power Factor1.0Voltage (Vac)120/208 or 127/220Voltage Regulation Range (Vac)≤+/- 1 % with Balanced Load, ≤ +/- 2 % with Unbalanced LoadFrequency (Hz)60/50 Hz, autoselect (synchronizable from 40 ~ 70)WaveformPure Sinosoidal WaveHarmonic Distortion THDv≤ 2% (linear load), ≤ 4% (non-linear load)Transfer Time (ms)0.0 ms(True On Line)Tipo de conexiónThree Phase Star, (3 Phases + Neutral + Ground), optional: Delta (3 Phases + Ground)Overload&lt; 105% continuous, 105% to 110% 60 min., 110% to 125% 10 min., 125% to 150% 60 s.,&gt; 150% immediate switch to Bypass

 Battery Bank

 ModelUPS-IND MR1 1380 (80 kVA)

UPS-IND MR1 13140 (140 kVA)

Voltage (Vdc)Adjustable +/-96 ~ +/-120Battery CapacityUp to 160 9 Ah 12 V BatteriesWithout Batteries (External Battery Bank)Battery TypeLead Acid (Sealed &amp; Maintenance Free)Full load backup time (min)5 – 13\*5 – 15\*(depending on the Battery Bank)Maximum Load Current (A)8 A for each power module (adjustable)Battery BankUp to 4 Series (each Series: 4 packs of 10 Batteries)Requires External Bank\* Consult with your Industronic Advisor.

 Physical and mechanical

 ModelUPS-IND MR1 1380 (80 kVA)

UPS-IND MR1 13140 (140 kVA)

Audible Noise (dB)&lt;&lt;50 ~ 55, at 1 meterOperating Temperature (°C)0 ~ 40Relative Humidity0 ~ 95% without CondensationMaximum Operating Altitude (m.a.s.l.)2,000 al 100%CabinetBaked electrostatic Epoxy coated SteelDimensions, height x width x depth (mm)2010 x 600 x 1100Dimensions, height x width x depth (mm)926 (with batteries)537

 Technology

 ModelUPS-IND MR1 1380 (80 kVA)

UPS-IND MR1 13140 (140 kVA)

Inverter3 level IGBT with PWM (Pulse Width Management) TechnologyRectifierHigh Efficiency PFC type with IGBT technologyOutput Isolation TransformerOptionalBattery StatusThermal Dissipation (kBTU / h)20.435.8Internal BypassTwo Bypass Modes: Automatic Static &amp; Manual Bypass Switch for MaintenanceParalleling4 Modules for N+1 or N+X in the same unit and 2 Units in parallel8 Modules for N+1 or N+ X in the same unit and 2 Units in parallelCertificacionesCE-62040-1, CE 62040-2, ISO 9001:2015, NOMInterfaz de ComunicaciónRS232, Puerto USB, 3 señales de salida contacto seco, tarjeta de red SNMP, Ranura adicional para Tarjeta de RedPantalla Digital táctilMuestra: Voltaje de entrada y salida, Capacidad de carga, Voltaje de baterías, Mímico de estado operativo, Módulos Operando y LEDS indicadoresAlarmasBatería Baja, Falla de Alimentación, Falla de UPS, Falla de Inversor, Falla de Rectificador, etc.ProtecciónBatería Baja, Sobrecarga, Corto circuito, Sobretemperatura, etc.

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)