---
title: "UPS-IND HF 1300 R1"
url: "https://grupoindustronic.com/en/product/ups-ind-hf-1300-r1/"
date: "2024-10-03"
modified: "2024-11-11"
type: "producto"
lang: "en"
---

UPS-IND HF 1300 R1 | Grupo Industronic                                       [](#)

 # UPS-IND HF 1300 R1

###### Uninterruptible Power Supply (UPS)

  ![UPS-IND HF 1300 R1](https://grupoindustronic.com/wp-content/uploads/2024/09/UPS-R1-Baja-Frecuencia.png)

  ![](https://grupoindustronic.com/wp-content/uploads/2024/09/UPS-R1-Baja-Frecuencia.png)

 ## UPS-IND HF 1300 R1

###### Uninterruptible Power Supply (UPS)

  ###### 60, 120, 200 kVA

 Capacity

  2 Year Warranty

Manufactured in Mexico

 The UPS-IND HF 1300 R1 is an advanced solution that incorporates inverter technology, making it a versatile and efficient option for a wide range of applications. Designed specifically for the industrial sector, this equipment ensures continuity of power supply, protecting critical equipment and operational processes from unexpected interruptions.

- On-line double conversion
- Double DSP for high reliability and performance
- Inverter with 3-level IGBT technology
- Dual Input Power Supply: Normal and Bypass
- UPS and Battery Self Test function
- Flexible Battery Configuration (29 to 40)
- Emergency Power Off (EPO)
- SNMP network card
- Battery charge monitoring and management
- Electronic Cards with Anticorrosive Cover.
- Easy on-site paralleling
- Output Isolation Transformer
- Shared battery bank for 2 UPS
- Compatible with Lithium Batteries

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ Datasheet UPS-IND HF 1300 R1 ](https://industronicservice.zendesk.com/hc/es-419/articles/34175782972691-UPS-IND-HF-1300-R1)

 Share: [Correo](mailto:?subject=UPS-IND%20HF%201300%20R1&body=https://grupoindustronic.com/en/product/ups-ind-hf-1300-r1/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/ups-ind-hf-1300-r1/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/ups-ind-hf-1300-r1/)

 #### Characteristics

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/Doble-conversio%CC%81n-en-li%CC%81nea.png)

###### On-line double conversion

Guarantees a clean and stable output voltage at all times, regardless of power supply variations.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/control-DSP.png)

###### Dual DSP

Dual Digital Signal Processor (DSP) high precision and high speed control for maximum system performance.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2024/09/3-niveles-1.png)

###### 3-Level Inverter

Management with IGBT technology adaptable to higher powers, operating at high speed and higher efficiency.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2024/09/dual-input.png)

###### Dual Input Power Supply

Dual Input power supply (Normal and Bypass) guarantees operation with mains and battery power.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2024/09/ups2.png)

###### Flexible battery configuration

Flexible battery configuration (29 to 40Ah).

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/Sistema-de-monitoreo-inteligente-para-bateri%CC%81as.png)

###### Monitoring and management of battery charging

It allows optimizing the charge and useful life of the batteries, guaranteeing energy backup.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/conexion-en-paralelo.png)

###### Easy on-site walling

Paralleling technology for up to 4 devices.

#### Applications

 ![Heavy Industry](https://grupoindustronic.com/wp-content/uploads/2020/02/industria-pesada.png)

###### Heavy Industry

Protect high power equipment against overloads and frequency variations.

 ![Industry](https://grupoindustronic.com/wp-content/uploads/2020/02/industria.png)

###### Industry

Maintain stability of industrial machinery even during power fluctuations and voltage spikes.

 ![Marine Platforms](https://grupoindustronic.com/wp-content/uploads/2020/02/plataformas-marinas.png)

###### Marine Platforms

Protect communication and control equipment on offshore platforms from power fluctuations.

 ![Medical Equipment](https://grupoindustronic.com/wp-content/uploads/2020/04/hospital.png)

###### Medical Equipment

Prevent failure of critical medical equipment during power outages and surges.

 ![Precision Instruments](https://grupoindustronic.com/wp-content/uploads/2020/02/maquinaria-herramienta-y-de-control-numerico.png)

###### Precision Instruments

Ensure accuracy of sensitive instruments against electrical fluctuations and harmonics.

 ![Train, Subway](https://grupoindustronic.com/wp-content/uploads/2020/04/APPS2.png)

###### Train, Subway

Keep train and subway signaling and control systems operational in the event of power failures.

  &gt;

 &lt;

#### Technical Specifications

 Input

 **Model**

**UPS IND 1360 R1****UPS IND 13120 R1****UPS IND 13200 R1**Overload ProtectionThermomagnetic circuit breaker Normal Input and Bypass InputNominal Voltage (Vac)120/208 – 127/220 – 220/380 – 230/400 – 240/415 – 254/440 – 266/460 – 277/480Voltage Range (Vac)-25% a +25%PhasesThree Phase Star (3 Phases + Neutral + Ground), Delta Optional (3 Phases + Ground)Frequency Range (Hz)60 Hz +/-10% (50 Hz optional)Factor de Potencia de Entrada≥ 0.99 at full loadTHDI≤ 5% to 100 non-linear load

 Output

 **Model****UPS IND 1360 R1****UPS IND 13120 R1****UPS IND 13200 R1**72/80108/120180/200AC to AC max efficiency94%Overload protectionThermomagnetic circuit breaker at outputOutput power factor0,9Voltage (Vac)120/208 – 127/220 – 220/380 – 230/400 – 240/415 – 254/440 – 266/460 – 277/480Voltage Regulation Range (Vac)+/- 1% (Linear Load)Frequency (Hz)60 +/- 0.2% (on batteries) (50 Hz optional)Waveform Pure SineHarmonic Distortion THDVTHD ≤ 1% (linear load)Transfer Time (ms)0.0 milliseconds (Line Mode to Battery Mode)Connection TypeThree-phase Star (3 Phase + Neutral + Ground), Delta Optional (3 Phase + Ground)Overload101 to 105% continuous operation, 106% to 130% 10 min to bypass, 131% to 155% 1 min to bypass, &gt; 150% immediate bypass

 Battery bank

 **Model****UPS IND 1360 R1****UPS IND 13120 R1****UPS IND 13200 R1**BUS Voltage (Vdc)Adjustable 348 to 480Battery Voltage12VBattery TypeLead acid (sealed and maintenance free) (Lithium Optional)Maximum Charger Charging Current (A)40 ampsBattery BankExternal

 Physical and mechanical

 **Model****UPS IND 1360 R1****UPS IND 13120 R1****UPS IND 13200 R1**Audible noise (dB) &lt; 65, at 1 meterOperating temperature (°C)-5 to 40 °CRelative Humidity0 ~ 95% non-condensingMaximum operating altitude (masl)Up to 1500 masl at 100% (up to 2,000 masl with 1% drift per 100 m)CabinetSteel with baked-on electrostatic epoxy coatingDimensions, height x width x depth (mm)2000 x 600 x 8002000 x 1000 x 8002000 x 1000 x 800UPS weight (kg)525 (without batteries)800 (without batteries)1150 (without batteries)

 Technology

 **Model****UPS IND 1360 R1****UPS IND 13120 R1****UPS IND 13200 R1**Inverter3 Level Inverter with PWM type IGBT technologyRectifierHigh Efficiency PFC type with IGBT technologyOutput Isolation TransformerIncludedBattery statusOn-line and real-time discharge informationThermal dissipation (kBTU/h) (full load)274168Internal Static BypassIncludedInternal Bypass MaintenanceIncludedParallelingUp to 4 equipmentsCertificationsCE-62040-1, CE 62040-2, ISO 9001:2015,Communications interfaceEPO, 12 dry contact signals (8 output 4 input), RS232/RS485, SNMP network card, Battery temperature sensorDigital touch screen displayDisplays: Input and Output Voltage, Charging Capacity, Battery Voltage, Operating Status Mimic, LED Indicators, Power On and Off ButtonsAlarmsLow Battery, Abnormal Input, UPS Failure, Over Load, etc.ProtectionLow Battery, Overload, Short Circuit, Over Temperature, Under Voltage etc.

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)