 # UPS-IND HF 1300 N1

###### Uninterruptible Power Supply (UPS)

  ![](https://grupoindustronic.com/wp-content/uploads/2024/06/UPS-13300-480V.png)

  ![](https://grupoindustronic.com/wp-content/uploads/2024/06/UPS-13300-480V.png)

 ## UPS-IND HF 1300 N1

###### Uninterruptible Power Supply (UPS)

  ###### 300 - 800 kVA

 Capacity

  2 Year Warranty

Manufactured in Mexico

 The UPS-IND HF 1300 N1 provides power backup for critical loads, including telecommunications, laboratory equipment and intelligent buildings.

- BESS (Energy Storage System) Capability
- On-line double conversion
- Inverter with three-level technology
- Power factor 1.0
- Power factor correction
- Intelligent fan control
- High AC/AC efficiency up to 97%.
- Rectifier and inverter with 5th generation IGBTs
- Maintenance bypass
- Automatic electronic bypass
- Automatic input protection cut-off
- Battery charging management
- SNMP, RS485, MODBUS communications card
- Lead acid batteries
- N+t capacity and N+X+1 redundancy paralleling technology (Up to 8 units)
- Ability to share battery bank for parallel systems (Lead acid batteries only)

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ Datasheet UPS-IND HF 1300 N1 ](https://industronicservice.zendesk.com/hc/es-419/articles/31941348160659-UPS-IND-HF-1300-N1)

 Share: [Correo](mailto:?subject=UPS-IND%20HF%201300%20N1&body=https://grupoindustronic.com/en/product/ups-ind-hf-1300-n1/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/ups-ind-hf-1300-n1/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/ups-ind-hf-1300-n1/)

 #### Characteristics

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2024/06/Icono-BESS.png)

###### BESS capability

The Battery Energy Storage System (BESS) provides a solution to efficiently manage and store energy.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/Doble-conversio%CC%81n-en-li%CC%81nea.png)

###### On-line double conversion

Guarantees a clean and stable output voltage at all times, regardless of power supply variations.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/05/fp1.png)

###### Power factor

The 1.0 power factor ensures efficiency and performance, optimizing the electrical system.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/power-factor-corrector.png)

###### Power factor correction

Increased efficiency in UPS operation, reducing voltage and current lag.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/ventilacion-inteligente.png)

###### Intelligent ventilation control

Automatic speed change according to the capacity of the load demanded, reduces noise and extends the life of the fans.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/control-DSP.png)

###### DSP control

Digital Signal Processor (DSP) maintains high precision control and speed for maximum system performance.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/inverson-con-tecnologia-IGBT.png)

###### IGBT technology

Management adaptable to higher powers, operating at high speed and switching efficiency.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/Tarjeta-de-red-SNMP.png)

###### SNMP Network Card

Friendly monitoring of the equipment, issuing timely alerts in case of unfavorable events in the electrical network.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/bypass.png)

###### Electronic Bypass

Automatic, ensures continuity of power to connected devices even in case of equipment failure.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/conexion-en-paralelo.png)

###### Parallel Technology

N+1 capacity and N+X+1 redundancy (up to 8 units).

### Video

#### Applications

 ![Buildings](https://grupoindustronic.com/wp-content/uploads/2020/02/edificios-comerciales.png)

###### Buildings

Protect elevators, HVAC systems and other critical equipment against electrical variations and power interruptions.

 ![Commercial buildings](https://grupoindustronic.com/wp-content/uploads/2020/04/centro-comer.png)

###### Commercial buildings

Protects HVAC systems, lighting and lifts from electrical fluctuations and power outages.

 ![Computer equipment](https://grupoindustronic.com/wp-content/uploads/2020/02/computadoras.png)

###### Computer equipment

Protect computers and peripherals against power surges and surges.

 ![Data Centers](https://grupoindustronic.com/wp-content/uploads/2020/02/centros-de-datos_data-center.png)

###### Data Centers

Ensure continuity and stability in servers and critical storage systems.

 ![Lab equipment](https://grupoindustronic.com/wp-content/uploads/2020/04/eq-analisis.png)

###### Lab equipment

Ensure the accuracy of laboratory equipment by protecting it from electrical variations.

 ![Regional Office Building](https://grupoindustronic.com/wp-content/uploads/2020/02/edificios-inteligentes.png)

###### Regional Office Building

Ensures the stability of critical systems and office equipment in the event of power outages.

 ![Sensitive Loads](https://grupoindustronic.com/wp-content/uploads/2020/02/servidores-1.png)

###### Sensitive Loads

Protect medical devices and sensitive equipment from electrical variations and transients.

 ![Telecommunication](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-equipo-de-telecomunicacion.png)

###### Telecommunication

Ensure the continuity of telecommunications services in the event of power surges.

  &gt;

 &lt;

#### Technical Specifications

 Input

 **Model UPS-IND HF 1300****13300****13400****13500****13600****13800**Capacity (kW/kVA)300/300400/4000500/500600/600800/800Voltage (Vac)277/480Overload protectionInput circuit breaker and bypass switchLine voltage range (Vac)-40% to +15% (-25% to +15% at 100%)PhasesThree-phase Star, 3-phase + Neutral + Ground / Delta (3-phase + Ground)Frequency (Hz)50/60 ± 10 %THDi≤ 3% at 100% resistive load / ≤5% at 100% non-linear loadInput power factor≥ 0.99

 Output

 **Model UPS-IND HF 1300****13300****13400****13500****13600****13800**Overload protectionSwitch on outputOutput power factor1.0Voltage (Vac)277/480Voltage regulation range±1%Frequency (Hz)50/60 Hz +/-0.5%Waveform (THDv)Sine Wave Pure, THD ‘ 1% (Linear Load); ‘ 3% (Non-Linear Load)Transfer time (ms)0.0, True OnlineConnection typeThree-phase Star, 3-phase + Neutral + Ground / Delta (3-phase + Ground)Overload100%-105% 60 min; 106%-125% 10 min; 126%-150% 1 minEfficiency96%Load unbalance capability100%Power returnSupports up to 100% of its capacityPeak factor≤ 3.1

 Physical and mechanical

 **Model UPS-IND HF 1300****13300****13400****13500****13600****13800**Audible noise (db)&lt; 75, at 1 meter&lt; 80, at 1 meterMTBF (h)233.000Operating temperature (ºC)-5 ~ 40Relative Humidity 0 ~ 95% without condensationMaximum operating altitude (m.a.s.l.)1500CabinetIP 20 / Steel with Electrostatic Epoxy Baked-on Epoxy PaintingDimensions (mm): Height x Width x Depth (mm)1000 x 900 x 19501400 x 900 x 1950Weight (Kg) (Batteries not included)7501150

 Technology

 **Model UPS-IND HF 1300****13300****13400****13500****13600****13800**Conversion TypeDouble Conversion Online (True Online)RectifierHigh Power Factor IGBT typeInverter Switching ElementsIGBT with PWM Pulse Width Modulated TechnologyFiltersPFC to Reduce Harmonic Content (RMS)Battery StatusReal-Time On-Line and Discharge Information with 3% AccuracyThermal Dissipation (kBTU/h)30.740.952.963.584.4Internal BypassTwo Bypasses: one automatic static and one manual for maintenanceLatchingParalleling by Capacity and/or Redundancy N + 1 (up to 8 equipments)CertificationsCE-IEC 62040 -1, ISO 9001:2015, NOMCommunication interfaceRS485 / SNMP/ Dry Contacts / MODBUSDisplay (color LCD)7 inches touch type + LEDs, with Backlight: Input and Output Voltage, Load Capacity, Battery Voltage, Operational StatusAlarmOverload, Abnormal Input, Low Batteries, FaultProtectionOutput Short Circuit, Overload, Overtemperature, Low Battery Voltage, High/Low Output Voltage

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)