title: "UPS-IND HF 1300 M1 (Lithium Ion)"
url: "https://grupoindustronic.com/en/product/ups-ind-hf-1300-m1-lithium-ion/"
date: "2023-09-18"
modified: "2024-12-30"
type: "producto"
lang: "en"
---

UPS-IND HF 1300 M1 (Lithium Ion) | Grupo Industronic                                       [](#)

 # UPS-IND HF 1300 M1 (Lithium Ion)

###### Uninterruptible Power Supply (UPS)

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 ## UPS-IND HF 1300 M1 (Lithium Ion)

###### Uninterruptible Power Supply (UPS)

  ###### 10 ~ 30 kVA

 Capacity

  2 Year Warranty

Manufactured in Mexico

 The UPS-IND HF 1300 M1 model has a better performance, due to its faster and more efficient process. It favors a longer life (8 to 10 years) both in the UPS and in the Lithium Ion battery bank. The latter offers a 55% reduction in footprint and is 50% light

- Dual input power supply: Normal and Bypass
- Long life Lithium Ion batteries
- Flexible battery configuration
- Footprint Reduced
- Lower carbon footprint
- Parallel technology
- UL-1778 Certificate

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ Datasheet UPS-IND HF 1300 M1 (Lithium Ion) ](https://industronicservice.zendesk.com/hc/es-419/articles/22991859789203-UPS-IND-HF-1300-M1-Ion-litio-10-30-kVA-)

##   ![Manuales](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) User Manuals

- [ UPS-IND HF 1300 M1 (Lithium Ion) Handbook ](https://industronicservice.zendesk.com/hc/es-419/articles/21658024219411-UPS-IND-HF-1300-M1-Ion-litio-)

##   ![Garantías](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Warranties

- [ UPS-IND HF 1300 M1 (Ion litio) Warranty ](https://industronicservice.zendesk.com/hc/es-419/articles/360056939794-Garant%C3%ADa-Sistema-Ininterrumpible-de-Energ%C3%ADa-UPS-IND)

 Share: [Correo](mailto:?subject=UPS-IND%20HF%201300%20M1%20(Lithium%20Ion)&body=https://grupoindustronic.com/en/product/ups-ind-hf-1300-m1-lithium-ion/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/ups-ind-hf-1300-m1-lithium-ion/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/ups-ind-hf-1300-m1-lithium-ion/)

 #### Características

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2021/01/dual-input.png)

###### Dual Input Power Supply

Dual Input Power Supply (Normal and Bypass)

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2023/08/icono_bateria-ionlitio_UPS-2.png)

###### Long life lithium-ion batteries

They offer higher energy density and extend the life of your equipment by 8 to 10 years.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/05/ups2.png)

###### Flexible battery configuration

Flexible battery configuration (1 to 3 modules of 50 Ah)

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2021/03/carcat-ups-m1.png)

###### Footprint Reduced

The M1 generation UPS provides a better user experience and better footprint, with a 55% footprint reduction.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/Modalidad-ECO-IND.png)

###### Lower carbon impact

Lithium-ion batteries contribute to a lower carbon footprint.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/conexion-en-paralelo.png)

###### Parallel technology

Paralleling technology for up to 4 units.

### Video

#### Applications

 ![Audiovisual Systems](https://grupoindustronic.com/wp-content/uploads/2020/04/audiovisual.png)

###### Audiovisual Systems

Ensure the operability of audiovisual equipment against electrical fluctuations.

 ![Banks](https://grupoindustronic.com/wp-content/uploads/2020/02/bancos.png)

###### Banks

Protect servers, terminals and banking transaction systems against power interruptions.

 ![Buildings](https://grupoindustronic.com/wp-content/uploads/2020/02/edificios-comerciales.png)

###### Buildings

Protect elevators, HVAC systems and other critical equipment against electrical variations and power interruptions.

 ![Call Centers](https://grupoindustronic.com/wp-content/uploads/2020/02/call-centers.png)

###### Call Centers

Avoid interruptions in call centers by protecting servers and communication equipment.

 ![Commercial buildings](https://grupoindustronic.com/wp-content/uploads/2020/04/centro-comer.png)

###### Commercial buildings

Protects HVAC systems, lighting and lifts from electrical fluctuations and power outages.

 ![Regional Office Building](https://grupoindustronic.com/wp-content/uploads/2020/02/edificios-inteligentes.png)

###### Regional Office Building

Ensures the stability of critical systems and office equipment in the event of power outages.

 ![Robotics](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-robotica.png)

###### Robotics

Maintain the accuracy of robotic systems during power fluctuations and power surges.

 ![Telecommunication](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-equipo-de-telecomunicacion.png)

###### Telecommunication

Ensure the continuity of telecommunications services in the event of power surges.

  &gt;

 &lt;

#### Technical Specifications

 Input

 Model UPS-IND HF1310 M1

1315 M1

1320 M1

1330 M1

Capacity (W/ VA)10000/1000015000/1500020000/2000030000/30000Voltage (Vca)208/220Overload ProtectionThermal magnetic input circuit breaker and Thermal magnetic bypass circuit breakerVoltage Range (Vac)156 a 260 (Line to Line): -29%, +18%PhaseThree Phase Star, 3 Phases + Neutral + Ground, optional: Delta (3 Phases + Ground)Frequency Range (Hz)40 ~ 70Input Power Factor≥ 0.99 at full loadTHDi≤ 3%

 Output

 Model UPS-IND HF1310 M1

1315 M1

1320 M1

1330 M1

AC to AC Maximum Efficiency94 %Overload ProtectionThermal magnetic output circuit breakerOutput Power Factor1.0Voltage (Vac)190/200/208 ±1%(L-L)±%Voltage Regulation Range (Vac)≤+/- 1 %Frequency (Hz)60 +/- 0.1% (Battery mode), Optional: 50 HzWaveformPure sinosoidal waveHarmonic Distortion THDv≤ 1% (Linear load), ≤ 4% (Non linear load)Transfer Time (ms)0.0 ms(True On Line)Connection TypeThree Phase Star, 3 Phases + Neutral + Ground, optional: Delta (3 Phases + Ground)Overload&lt;&lt; 105% continuous, 105% to 110% 60 min., 110% to 125% 10 min., 125% to 150% 60 s., &gt; 150% immediate switch to BypassEnergy returnDoes not support energy return

 Battery Bank

 Model UPS-IND HF1310 M1

1315 M1

1320 M1

1330 M1

Voltage (Vcd)+120(96+120)Battery Capacity50 AhBattery Type15 standard (extended time available upon requestFull load backup time (min)5 min Standard (Extended Time available upon request)Maximum Load Current (A)Maximum Load Current (A) 0.1 – 1C (default 0.5 C)Internal Battery Bank1 package2 package3 packageUseful life time8 to 10 years at 40ºC. At higher temperatures their useful life is considerably reduced. To keep the batteries healthy we recommend recharging them at least once every 3 months and to avoid damage recharge them every 6 months.

 Physical &amp; Mechanical

 Model UPS-IND HF1310 M1

1315 M1

1320 M1

1330 M1

Audible Noise (dB)&lt;60, at 1 meter&lt;65, at 1 meterOperating Temperature (°C)-5 ~ 40Relative Humidity0 ~ 95% without CondensationMaximum Operating Altitude (m.a.s.l.)2,000 at 100%CabinetBaked electrostatic Epoxy coated SteelDimensions, height x width x depth (mm)1250 x 378 x 995UPS Weight (kg)93 / 135 / 15094 / 177 / 17094 / 177 / 172112 / 220 / 198UPS packaged weight (kg)199241284

 Technology

 Model UPS-IND HF1310 M1

1315 M1

1320 M1

1330 M1

Inverter3 level IGBT technology for higher efficiency and minimized interference to gridRectifierHigh Efficiency PFC type with IGBT technologyOutput Isolation TransformerOptionalBattery StatusReal Time Online/Discharge InformationThermal Dissipation (kBTU / h)2.053.074.106.15Internal BypassTwo Bypass Modes: Automatic Static &amp; Manual Bypass Switch for MaintenanceParallelingN + 1 (up to 4 units)CertificationsUL-1778, CE-62040-1, CE 62040-2, ISO 9001:2015Communications InterfaceRS485 + EPO, 5 dry contact output signals, 1 dry contact input, RS232, SNMP network cardDigital Touch ScreenDisplays: Input and output voltage, Load capacity, Battery voltage, Operating Status Mimic and LEDs IndicatorsAlarmsLow Battery, Abnormal Input, UPS Failure, etc.ProtectionLow Battery, Overload, Short Circuit, Over Temperature, etc.

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)