---
title: "UPS-IND HF 1300 M1 (40-200 kVA)"
url: "https://grupoindustronic.com/en/product/ups-ind-hf-1300-m1-60-to-200-kva/"
date: "2022-03-09"
modified: "2025-05-19"
type: "producto"
lang: "en"
---

UPS-IND HF 1300 M1: High-efficiency 60-200 kVA power backup                                       [](#)

 # UPS-IND HF 1300 M1 (40-200 kVA)

###### Uninterruptible Power Supply (UPS)

  ![UPS-IND HF 1300 M1](https://grupoindustronic.com/wp-content/uploads/2022/02/UPS-IND-HF-1300-M1-new.png)

  ![](https://grupoindustronic.com/wp-content/uploads/2022/02/UPS-IND-HF-1300-M1-new.png)

 ## UPS-IND HF 1300 M1 (40-200 kVA)

###### Uninterruptible Power Supply (UPS)

  ###### 40 ~ 200 kVA

 Capacity

###### +/- 1%

 Voltage regulation

  2 Year Warranty

 The high frequency UPS-IND HF 1300 M1 provides power backup solutions for critical loads, thanks to its three-level inverter with PWM type IGBT technology provides adaptive management to higher powers, operating at high speed and higher efficiency.

- On-line double conversion
- 1.0 Power Factor
- High Efficiency of 97%
- Lower Footprint
- Dual DSP for high reliability and performance
- 2 Optional slot for SNMP and dry contact
- 3 Level IGBT Technology Inverter
- Dual input power supply: Mains and bypass
- Anti-corrosion resistant coating for all PCB boards

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ UPS-IND 1300 M1 Datasheet ](https://grupoindustronic.com/wp-content/uploads/2022/03/Datasheet-UPS-IND-1300-M1-1.pdf)

##   ![Manuales](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) User Manuals

- [ UPS-IND 1300 M1 Handbook ](https://industronicservice.zendesk.com/hc/es-419/articles/11180732918675-Manual-UPS-1300-M1-60-200-kVA-1360-1380-13100-13120-13160-13200-)

##   ![Garantías](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Warranties

- [ UPS-IND Warranty ](https://industronicservice.zendesk.com/hc/es-419/articles/36880833951123-UPS-IND-Warranty)

 Share: [Correo](mailto:?subject=UPS-IND%20HF%201300%20M1%20(40-200%20kVA)&body=https://grupoindustronic.com/en/product/ups-ind-hf-1300-m1-60-to-200-kva/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/ups-ind-hf-1300-m1-60-to-200-kva/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/ups-ind-hf-1300-m1-60-to-200-kva/)

 #### Features

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/Doble-conversio%CC%81n-en-li%CC%81nea.png)

###### On Line Double Conversion

Guarantees clean and stable voltage output despite irregularities on the input.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/05/fp1.png)

###### 1.0 Power Factor

The 1.0 power factor ensures efficiency and performance, optimizing the electrical system

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/control-DSP.png)

###### Dual DSP

Dual Digital Signal Processor (DSP) high precision and high speed control for maximum system performance.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2022/03/97-eficiencia22-1-e1646263978840.png)

###### High Efficiency

AC/AC efficiency up to 97%

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2021/01/3-niveles.png)

###### 3 Level IGBT

3 Level IGBT Technology Inverter

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/doble-bypass.png)

###### Doble Bypass

Automatic bypass ensures continuity of power to connected devices even in the event of equipment failure.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/Modalidad-ECO-IND.png)

###### ECO-IND Mode

99% efficiency in ECO mode (when bypass voltage and frequency are within the permitted range).

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2021/01/anticorros.png)

###### Anti-corrosion PCB boards

Anti-corrosion resistant coating for all PCB boards

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/conexion-en-paralelo.png)

###### Parallelable Technology

Parallel by capacity N + 1 or redundancy N+X+1 (Up to 8)

### Video

#### Applications

 ![Audiovisual Systems](https://grupoindustronic.com/wp-content/uploads/2020/04/audiovisual.png)

###### Audiovisual Systems

Ensure the operability of audiovisual equipment against electrical fluctuations.

 ![Banks](https://grupoindustronic.com/wp-content/uploads/2020/02/bancos.png)

###### Banks

Protect servers, terminals and banking transaction systems against power interruptions.

 ![Commercial buildings](https://grupoindustronic.com/wp-content/uploads/2020/04/centro-comer.png)

###### Commercial buildings

Protects HVAC systems, lighting and lifts from electrical fluctuations and power outages.

 ![Computer Rooms](https://grupoindustronic.com/wp-content/uploads/2020/02/computadoras.png)

###### Computer Rooms

Protect servers and network equipment against electrical fluctuations and power surges.

 ![Precision Instruments](https://grupoindustronic.com/wp-content/uploads/2020/02/maquinaria-herramienta-y-de-control-numerico.png)

###### Precision Instruments

Ensure accuracy of sensitive instruments against electrical fluctuations and harmonics.

 ![Regional Office Building](https://grupoindustronic.com/wp-content/uploads/2020/02/edificios-inteligentes.png)

###### Regional Office Building

Ensures the stability of critical systems and office equipment in the event of power outages.

 ![Robotics](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-robotica.png)

###### Robotics

Maintain the accuracy of robotic systems during power fluctuations and power surges.

  &gt;

 &lt;

#### Technical Specifications

 Input

 Modelo: UPS-IND HF1340 M1

1360 M1

1380 M1

13100 M1

13120 M1

13160 M1

13200 M1

Capacity (kW/ kVA)240/4060/6080/80100/100120/120160/160200/200Voltage(Vca)120/208, 127/220, 220/380, 230/400, 254/440, 266/460, 277/480

Overload ProtectionThermal magnetic input circuit breaker and Thermal magnetic bypass circuit breakerVoltage Range (Vac)+/- 20% (Line to Line)PhaseThree Phase Star, 3 Phases + Neutral + Ground, optional: Delta (3 Phases + Ground)Frequency Range (Hz)40 ~ 70Input Power Factor≥ 0.99 at full load

THDi≤ 3%

 Output

 Modelo: UPS-IND HF1340 M1

1360 M1

1380 M1

13100 M1

13120 M1

13160 M1

13200 M1

AC to AC Maximum Efficiency97 %Overload ProtectionThermal magnetic output circuit breakerOutput Power Factor1.0Voltage (Vac)120/208, 127/220, 220/380, 230/400, 254/440, 266/460, 277/480

Voltage Regulation Range (Vac)+/- 1 %Frequency (Hz)60 +/- 0.1% (battery mode) (optional: 50 Hz)WaveformPure sinoidal waveHarmonic Distortion THDv≤ 1% (carga lineal), ≤ 4% (non linear load)Transfer Time (ms)0.0 milisegundos (true on line)Connection TypeThree phase star, 3 phases + neutral + ground, optional: delta (3 phases + ground)3Overload101 a 105% continuous, 106 a 110% 60 min, 111 a 125% 10 minutos,126 a 150% 60 segundos, &gt; 150% immediate switch to bypass

 Battery Bank

 Modelo: UPS-IND HF1340 M1

1360 M1

1380 M1

1300 M1

13120 M1

13160 M1

13200 M1

Voltage (Vcd)+/-192 (+/-168 a +/- 288 adjustable)Full load backup time (min)5 standard (extended time available upon request)Battery TypeLead Acid (Sealed &amp; Maintenance Free)Maximum Load Current (A)3060Banco de bateríasInternalExternal

 Physical &amp; Mechanical

 Physical &amp; Mechanical1340 M11360 M11380 M113100 M113120 M113160 M113200 M1Audible Noise (db)&lt; 65 at 1 meterOperating Temperature (ºC)0 to 40Relative Humidity0 – 95% without condensationMaximum Operating Altitude (m.a.s.l.)2400 at 100%, 3000 at 96%CabinetBaked electrostatic Epoxy coated steelDimensions x height x width x depth (mm)1600 x 950 x 10001800 x 1100 x 1220UPS net weight (kg)4807209601100120014601610

 Technology

 **Modelo: UPS-IND HF****1340 M1****1360 M1****1380 M1****1300 M1****13120 M1****13160 M1****13200 M1**Inverterlevel IGBT technology for higher efficiency and minimized interference to gridRectifierHigh Efficiency PFC type with IGBT technologyOutput Isolation TransformerOptionalBattery StatusReal Time Online/Discharge InformationThermal Dissipation (kBTU / h)4.16.18.210.212.316.420.5Internal BypassTwo Bypass Modes: Automatic Static &amp; Manual Bypass Switch for MaintenanceParallelingParallelable by Capacity and/or Redundancy N + 1 (up to 8 units)CertificationsCE-62040-1, CE 62040-2, ISO 9001:2015Communications InterfaceRS485 + EPO, 5 dry contact output signals, 1 dry contact input, RS232, SNMP network cardDigital Touch ScreenDisplays: Input and output voltage, Load capacity, Battery voltage, Operating Status Mimic and LEDs IndicatorsAlarmsLow Battery, Abnormal Input, UPS Failure, etc.ProtectionLow Battery, Overload, Short Circuit, Over Temperature, etc.

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)