---
title: "UPS-IND HF 1300"
url: "https://grupoindustronic.com/en/product/ups-ind-hf-1300-300-600/"
date: "2021-07-12"
modified: "2024-12-30"
type: "producto"
lang: "en"
---

Uninterruptible Power Supply | UPS-IND | Grupo Industronic                                       [](#)

 # UPS-IND HF 1300

###### Uninterruptible Power Supply (UPS)

  ![UPS-IND 1300 HF](https://grupoindustronic.com/wp-content/uploads/2020/06/hf-1300-copia.png)

  ![](https://grupoindustronic.com/wp-content/uploads/2020/06/hf-1300-copia.png)

 ## UPS-IND HF 1300

###### Uninterruptible Power Supply (UPS)

  ###### 300~600 kVA

 Capacity

###### +/-1%

 Voltage regulation

  2 Year Warranty

 High Frequency, On Line, Double Conversion UPS is the most complete solution for protecting critical loads, allowing the user continuous operation and clean, regulated voltage.

- On Line Double Conversion
- 1.0 Power Factor
- Battery Backup
- 97% High Efficiency
- Parallelable Technology
- DSP Control
- IGBT Technology
- SNMP Network Card
- Electronic Bypass

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ UPS-IND HF (300 ~ 600 kVA) Datasheet ](https://grupoindustronic.com/wp-content/uploads/2021/07/Datasheet-UPS-IND-HF-1300-300600k.pdf)

##   ![Manuales](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) User Manuals

- [ UPS-IND HF (300 ~ 600 kVA) Handbook ](https://industronicservice.zendesk.com/hc/es-419/articles/360059014213-Manual-UPS-IND-13300-HF-13400-HF-13500-HF-13600-HF-13800-HF-131000-HF-131200-HF)

##   ![Garantías](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Warranties

- [ UPS-IND Warranty ](https://industronicservice.zendesk.com/hc/es-419/articles/36880833951123-UPS-IND-Warranty)

 Share: [Correo](mailto:?subject=UPS-IND%20HF%201300&body=https://grupoindustronic.com/en/product/ups-ind-hf-1300-300-600/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/ups-ind-hf-1300-300-600/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/ups-ind-hf-1300-300-600/)

 #### Uninterrupted Power, True On Line

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/Doble-conversio%CC%81n-en-li%CC%81nea.png)

###### On Line Double Conversion

Guarantees clean and stable voltage output despite irregularities on the input.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/05/fp1.png)

###### 1.0 Power Factor

1.0 Power factor ensures optimized efficiency and performance of complete electrical system.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/power-factor-corrector.png)

###### Power Factor Correction

Reduces gap between voltage and current for higher efficiency and functionality.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/5-minutos-de-tiempo-de-respaldo.png)

###### Battery Backup

Ensures operational continuity with 5 minute standard battery backup time. Optional extended backup time may be added to adjust to specific needs.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/conexion-en-paralelo.png)

###### Parallelable Technology

Parallel by capacity or redundancy n + 1 (master-slave exempt); up to 8 units.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/control-DSP.png)

###### DSP Control

Digital Signal Processor sustains high precision control and speed for optimal system performance.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/IGBT.png)

###### IGBT Technology

High efficiency and fast switching controller that adapts to high power applications.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/Tarjeta-de-red-SNMP.png)

###### SNMP Network Card

Monitoring equipment alerts, controls and tracks current status of UPS from any off site location.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/bypass.png)

###### Electronic Bypass

Automatic bypass ensures operational continuity in the event of a failure.

### Video

#### Applications

 ![Commercial buildings](https://grupoindustronic.com/wp-content/uploads/2020/04/centro-comer.png)

###### Commercial buildings

Protects HVAC systems, lighting and lifts from electrical fluctuations and power outages.

 ![Computer equipment](https://grupoindustronic.com/wp-content/uploads/2020/02/computadoras.png)

###### Computer equipment

Protect computers and peripherals against power surges and surges.

 ![Data Centers](https://grupoindustronic.com/wp-content/uploads/2020/02/centros-de-datos_data-center.png)

###### Data Centers

Ensure continuity and stability in servers and critical storage systems.

 ![Lab equipment](https://grupoindustronic.com/wp-content/uploads/2020/04/eq-analisis.png)

###### Lab equipment

Ensure the accuracy of laboratory equipment by protecting it from electrical variations.

 ![Medical Equipment](https://grupoindustronic.com/wp-content/uploads/2020/04/hospital.png)

###### Medical Equipment

Prevent failure of critical medical equipment during power outages and surges.

 ![Regional Office Building](https://grupoindustronic.com/wp-content/uploads/2020/02/edificios-inteligentes.png)

###### Regional Office Building

Ensures the stability of critical systems and office equipment in the event of power outages.

 ![Telecommunication](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-equipo-de-telecomunicacion.png)

###### Telecommunication

Ensure the continuity of telecommunications services in the event of power surges.

  &gt;

 &lt;

#### Technical Specifications

 Input

 UPS IND HF

1322513300

13400

13500

13600

13225

13300

13400

13500

13600

Capacity (kW / kVA)225/225300/300400/400500/500600/600225/ 225300/300400/400500/500600/600Voltage (Vca)120/208, 127/220254/440, 266/460, 277/480Overload ProtectionThermal magnetic input circuit breaker and Thermal magnetic bypass circuit breakerOnline Voltage Range (Vca)+/- 20% at 100% Load, +/- 25% at 75% Load, +/- 30% at 50% LoadPhasesThree Phase Star, 3 Phases + Neutral + GroundFrequency(Hz)50/60 ± 10 %THDi≤ 2 % (at 100% Load); ≤ 4 % (at 50% Load)Input Power Factor≥ 0.99

 Output

 UPS IND HF

1322513300

13400

13500

13600

13225

13300

13400

13500

13600

Overload ProtectionThermal magnetic output circuit breakerOutput Power Factor1.0Voltage (Vca)120/208, 127/220254/440, 266/460, 277/480Voltage Regulation Range± 1%Frequency(Hz)50/60 ± 0.1% (Battery Mode), 50/60 ± 1 ~5 (Online Mode)Wave FormPure Sinosoidal Wave, THD ≤ 1% (Linear Load); ‹ 3% (Nonlinear Load)Transfer Time (ms)0.0, True OnlineConnection TypeStar, 3 Phases + Neutral + GroundOverload110% 60 min; 125% 10 min; 150% 1 minEfficency97%Load Imbalance Capacity100%

 Battery Bank

 UPS IND HF

1322513300

13400

13500

13600

13225

13300

13400

13500

13600

Voltage (Vcd)384 – 528 AdjustableBattery TypeLead Acid (Sealed &amp; Maintenance Free) / (Optional Nickel Cadmium)Full load backup time (min)5 min Standard (Extended Time available upon request)Maximum Load Current (A)25 – 10025 – 20025 – 10025 – 200Battery BankExternal Bank

 Physical &amp; Mechanical

 UPS IND HF

1322513300

13400

13500

13600

13225

13300

13400

13500

13600

Audible Noise (dB)&lt; 65, a 1 MeterMTBF (hrs)233,000Operatingl Temperature Range (°C)-5 ~ 40Relative Humidity0 ~ 95% without CondensationMaximum Operating Altitude (mamsl)3,000FinishIP 20, Baked Electrostatic Epoxy Coated SteelDimensions: height x width x depth (mm)1950 x 1800 x 9001950 x 1800 x 10001950 x 2300 x 12001950 x 1650 x 9001950 x 2150 x 900UPS Weight (kg)\*\*1850205022502800310015501650175022002300

 Technology

 UPS IND HF

1322513300

13400

13500

13600

13225

13300

13400

13500

13600

Conversion TypeOnline Double Conversion (True Online)RectifierIGBT type with High Power FactorInverter Conmutation ElementsGBT with PWM Pulse Width Management TechnologyFiltersPFC to Reduce Harmonic Distortion (2% RMS)Battery StatusReal Time Online/Discharge Information with 3% PrecisionThermal Dissipation (kBTU / h)23.531.742.352.963.523.531.742.352.063.5Internal BypassTwo Bypass Modes: Automatic Static &amp; Manual Bypass Switch for MaintenanceParallelingParallelable by Capacity and/or Redundancy N + 1 (up to 8 units)CertificationsCE-IEC 62040 -1, ISO 9001:2015, NOMCommunication InterfaceRS485 / SNMP/ Dry Contacts / MODBUSLCD Color ScreenBacklight: Input/Output Voltage, Load Capacity, Battery Voltage, Operation StatusAlarmOverload, Abnormal Input, Low Battery, FailureProtectionOutput Short Circuit, Overload, Overheating, Battery Low Voltage, High/Low Output Voltage

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)