Uninterruptible Power Supply (UPS)

UPS-IND HF 1300

Uninterruptible Power Supply (UPS)

UPS-IND HF 1300

80 ~ 200 kVA
Capacity
+/-1%
Voltage regulation
2 Year Warranty

This high frequency UPS provides uninterrupted backup in case of power interruption and integrated protection for critical loads such as data centers, telecom, lab equipment and smart building controls.

  • On Line Double Conversion
  • 1.0 Power Factor
  • Battery Backup
  • 96% High Efficiency
  • Parallelable Technology
  • DSP Control
  • IGBT Technology
  • SNMP Network Card
  • Electronic Bypass

Uninterrupted Power

Icono rayo
On Line Double Conversion
Guarantees clean and stable voltage output despite irregularities on the input.
Icono rayo
1.0 Power Factor
1.0 Power factor ensures optimized efficiency and performance of complete electrical system.
Icono rayo
Power Factor Correction
Reduces gap between voltage and current for higher efficiency and functionality.
Icono rayo
Battery Backup
Ensures operational continuity with 5 minute standard battery backup time. Optional extended backup time may be added to adjust to specific needs.
Icono rayo
Parallelable Technology
Parallel by capacity or redundancy n + 1 (master-slave exempt).
Icono rayo
DSP Control
Digital Signal Processor sustains high precision control and speed for optimal system performance.
Icono rayo
IGBT Technology
High efficiency and fast switching controller that adapts to high power applications.
Icono rayo
SNMP Network Card
Monitoring equipment alerts, controls and tracks current status of UPS from any off site location.
Icono rayo
Electronic Bypass
Automatic bypass ensures operational continuity in the event of a failure.

Applications

Commercial buildings
Commercial buildings
Commercial Security Systems
Commercial Security Systems
Computer equipment
Computer equipment
Data Centers
Data Centers
Lab equipment
Lab equipment
Medical Equipment
Medical Equipment
Regional Office Building
Regional Office Building
Telecommunication
Telecommunication

Technical Specifications

UPS IND HF
1380
13100
13120
13160
13200
1380
13100
13120
13160
13200
Capacity (kW / kVA) 80 / 80 100 / 100 120 / 120 160 / 160 200 / 200 80 / 80 100 / 100 120 / 120 160 / 160 200 / 200
Voltage (Vca) 120/208, 127/220 254/440, 266/460, 277/480
Overload Protection Thermal magnetic input circuit breaker and Thermal magnetic bypass circuit breaker
Online Voltage Range (Vca) +/- 20% at 100% Load, +/- 25% at 75% Load, +/- 30% at 50% Load
Phases Three Phase Star, 3 Phases + Neutral + Ground
Frequency(Hz) 40 – 70
Input Power Factor ≥ 0.99
UPS IND HF
1380
13100
13120
13160
13200
1380
13100
13120
13160
13200
Overload Protection Thermal magnetic output circuit breaker
Output Power Factor 1.0
Voltage (Vca) 120/208, 127/220 254/440, 266/460, 277/480
Voltage Regulation Range ± 1%
Frequency(Hz) 50/60 ± 0.1% (Modo de Baterías)
Wave Form Pure Sinosoidal Wave, THD ≤ 1% (Linear Load)
Transfer Time (ms) 0.0, True Online
Connection Type Star, 3 Phases + Neutral + Ground
Overload 105%~115% 60min; 116%~130% 10min; 131%~150% 1min; >150% 200ms
Efficency 96%
Load Imbalance Capacity 100%
UPS IND HF
1380
13100
13120
13160
13200
1380
13100
13120
13160
13200
Voltage (Vcd) 360 – 480 Adjustable
Battery Type Lead Acid (Sealed & Maintenance Free) / (Optional Nickel Cadmium)
Full load backup time (min) 5 min Standard (Extended Time available upon request)
Maximum Load Current (A) 20 30 30 40 50 20 30 30 40 50
Battery Bank External Bank
UPS IND HF
1380
13100
13120
13160
13200
1380
13100
13120
13160
13200
Audible Noise (dB) < 65, a 1 Meter
MTBF (hrs) 233,000
Operational Temperature (°C) 0 – 40
Relative Humidity 0 ~ 95% without Condensation
Maximum Operating Altitude (mamsl) 2,000 at 100%, 3,000 at 96%
Finish Baked Electrostatic Epoxy Coated Steel
Dimensions: height x width x depth (mm) 1600 x 950 x 900 1600 x 1450 x 900 1600 x 950 x 900 1600 x 1100 x 900
UPS Weight (kg)** 964 1086 1167 1335 1458 677 757 817 969 1077
UPS IND HF
1380
13100
13120
13160
13200
1380
13100
13120
13160
13200
Conversion Type Online Double Conversion (True Online)
Rectifier IGBT type with High Power Factor
Inverter Conmutation Elements GBT with PWM Pulse Width Management Technology
Filters PFC to Reduce Harmonic Distortion (2% RMS)
Battery Status Real Time Online/Discharge Information with 3% Precision
Thermal Dissipation (kBTU / h) 12 14 17 23 28 12 14 17 23 28
Internal Bypass Two Bypass Modes: Automatic Static & Manual Bypass Switch for Maintenance
Paralleling Parallelable by Capacity and/or Redundancy N + 1 (up to 8 units)
Certifications CE-IEC 62040 -1, ISO 9001:2015, NOM
Communication Interface RS485 / SNMP/ Dry Contacts / MODBUS
LCD Color Screen Backlight: Input/Output Voltage, Load Capacity, Battery Voltage, Operation Status
Alarm Overload, Abnormal Input, Low Battery, Failure
Protection Output Short Circuit, Overload, Overheating, Battery Low Voltage, High/Low Output Voltage

Power Calculator

Instantly calculate equipment capacity by filling in the missing information:

Cerrar
Whatsapp Whatsapp