UPS-IND 1200 HF: Reliable two-phase power backup                                       [](#)

 # UPS-IND 1200 HF Two Phase

###### Uninterruptible Power Supply (UPS)

-
-

-
-

-
-
-

-
-

-
-
-

-
-
-
-

-
-
-

-
-
-

-
-
-

-
-
-
-

-
-
-
-

-
-
-

-
-
-
-

-
-
-
-

-
-

-
-

- ![Indicators screen](https://grupoindustronic.com/wp-content/uploads/2025/01/Monitoreo-Remoto.webp)###### Indicators screen

    From here it is possible to know the main operating indicators of the UPS and to make configurations.
- ![Maintenance bypass](https://grupoindustronic.com/wp-content/uploads/2025/01/Bypass-de-mantenimiento-Sin-Fondo.webp)###### Maintenance Bypass

    Guarantees the continuity of operation even under maintenance conditions.
- ![SNMP](https://grupoindustronic.com/wp-content/uploads/2025/01/Puerto-SNMP.webp)###### SNMP Port

    Facilitates the monitoring of the equipment by issuing alerts to the user for quick action.
- ![toroidal transformer](https://grupoindustronic.com/wp-content/uploads/2025/01/Transformador-Sin-Fondo.webp)###### Toroidal transformer

    Allows the equipment to operate at 110V or 220V, giving it great versatility.

 ## UPS-IND 1200 HF Two Phase

###### Uninterruptible Power Supply (UPS)

  [ ![Amazon](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/logo-amazon.png) ](https://www.amazon.com.mx/stores/Industronic/page/A9B999EB-18DA-411C-B8A4-C1453C952E10?ref_=ast_bln) [ ![Mercado libre](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/logo-mercadolibre.png) ](https://listado.mercadolibre.com.mx/pagina/grupoindustronic/)

 ###### 6 &amp; 10 kVA

 Capacity

###### +/-1%

 Voltage regulation

  2 Year Warranty

 New high frecuency HF UPS is the optimum protection for complex electrical networks. Battery back up as well as voltage correction offer continuos protection to connected equipment.

- On Line Double Conversion
- Power Factor Correction
- Cold Start Function
- IGBT Technology
- Maintenance Bypass
- Electronic Bypass

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ UPS-IND HF 1200 (6 ~ 10 kVA) Datasheet ](https://industronicservice.zendesk.com/hc/es-419/articles/22669287526419-UPS-IND-1200-HF-6-y-10-kVA-)

##   ![Manuales](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) User Manuals

- [ UPS-IND HF 1200 (6 ~ 10 kVA) Handbook ](https://industronicservice.zendesk.com/hc/es-419/articles/360035664274-Manual-UPS-IND-HF-1206-UPS-IND-HF-1210-bif%C3%A1sico-6-10-kVA-)
- [ UPS-IND HF 1200 (6 ~ 10 kVA) Quick guide ](https://industronicservice.zendesk.com/hc/es-419/articles/360034895414-Gu%C3%ADa-r%C3%A1pida-de-Instalaci%C3%B3n-UPS-IND-1206-HF-y-UPS-IND-1210-HF)

##   ![Garantías](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Warranties

- [ UPS-IND Warranty ](https://industronicservice.zendesk.com/hc/es-419/articles/36880833951123-UPS-IND-Warranty)

##   ![Certificaciones](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Certifications

- [ NOM-NYCE UPS-IND HF 1206 ](https://grupoindustronic.com/wp-content/uploads/2024/06/NYC-2402C0E09029.pdf)
- [ EMTEK ](https://grupoindustronic.com/wp-content/uploads/2023/05/CE-UPS-IND-HF-1206-1210-IEC62040-2.pdf)
- [ CE ](https://grupoindustronic.com/wp-content/uploads/2023/05/UPS-IND-HF-1206UPS-IND-HF-1210-IEC62040-3.pdf)

 Share: [Correo](mailto:?subject=UPS-IND%201200%20HF%20Two%20Phase&body=https://grupoindustronic.com/en/product/ups-ind-1200-hf/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/ups-ind-1200-hf/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/ups-ind-1200-hf/)

 #### Uninterrupted Power

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/Doble-conversio%CC%81n-en-li%CC%81nea.png)

###### On Line Double Conversion

Guarantees clean and stable voltage output despite irregularities on the input.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/power-factor-corrector.png)

###### Power Factor Correction

Reduces gap between voltage and current for higher efficiency and functionality.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/cold-start.png)

###### Cold Start Function

Autonomous operation initiates directly from batteries.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/inverson-con-tecnologia-IGBT.png)

###### IGBT Technology

High efficiency and fast switching controller that adapts to high power applications.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/caracteristicas-amcr9.png)

###### Maintenance Bypass

Bypass switch enables safe UPS electrical isolation during maintenance or testing.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/bypass.png)

###### Electronic Bypass

Automatic bypass ensures operational continuity in the event of a failure.

### Video

#### Applications

 ![Computer equipment](https://grupoindustronic.com/wp-content/uploads/2020/02/computadoras.png)

###### Computer equipment

Protect computers and peripherals against power surges and surges.

 ![Control Equipment](https://grupoindustronic.com/wp-content/uploads/2020/04/EQUI-DE-CONTROL.png)

###### Control Equipment

Protect industrial automation and control systems against power outages and voltage spikes.

 ![IT Servers](https://grupoindustronic.com/wp-content/uploads/2020/02/servidores-1.png)

###### IT Servers

Protect servers and network equipment against power fluctuations and voltage drops.

 ![Lab equipment](https://grupoindustronic.com/wp-content/uploads/2020/04/eq-analisis.png)

###### Lab equipment

Ensure the accuracy of laboratory equipment by protecting it from electrical variations.

 ![Routers, Telecom, VoIP](https://grupoindustronic.com/wp-content/uploads/2020/02/routers_telecomunicaciones_VoIP.png)

###### Routers, Telecom, VoIP

Protect network and telecommunications equipment from power outages and voltage spikes.

 ![Servers](https://grupoindustronic.com/wp-content/uploads/2020/02/servidores.png)

###### Servers

Protect servers and network equipment against power fluctuations and voltage drops.

 ![Telecommunication](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-equipo-de-telecomunicacion.png)

###### Telecommunication

Ensure the continuity of telecommunications services in the event of power surges.

  &gt;

 &lt;

#### Technical Specifications

 Input

 UPS-IND HF

1206

1210

Capacity (kVA / kW)6/5.4 (optional 6/6)10/9 (optional 10/10)Input Voltage (V)220Overload ProtectionThermomagnetic switchRange (Accepted)– 20%, + 25% (at full load)Phases2 phases (2 wires + ground)Frequency40 – 70 (autodetection)Power Factor0.99

 Output

 UPS-IND HF

1206

1210

Output Power Factor1.0Voltage (Vca)120 / 208 / 220 / 230 / 240 (adjustable)Voltage Regulation Range± 1% (typical)Frequency (Hz)50 / 60 ± 0.2% (battery mode)Wave FormTHD pure sinusoidal wave ≤ 1% (linear load), ≤ 3% (non-linear load)Transfer Time (ms)0.0 (on line)Overload105%-125% 10min, 125%-150% 5 min, 150%-200% 5 s, &gt;200% 200 ms.Load unbalance capability100%Efficiency96%

 Battery Bank

 UPS-IND HF

1206

1210

Voltage (Vcd)192 standard (192 -240 adjustable)Battery Type12 volts 7.2 Ah / 12 volts 9 Ah (lead acid, maintenance-free)Battery Backup Time at Full Load (min)3 -5 min. at full load, 9-18 min. at half loadMaximum Load Current (A)1.0 – 3.0 (adjustable)Battery BankInternal

 Physical &amp; Mechanical

 UPS-IND HF

1206

1210

Audible Noise (dB)&lt; 55, at 1 meterMTBF (h)233,000Operational Temperature (°C)0 ~ 40 at full load, 50 at 90% of the loadRelative Humidity0 ~ 95% without condensationMaximum Operating Altitude (mamsl)2,300 at 100% , 3,100 at 85%CabinetElectrostatic baked epoxy coated steel, NEMA type 1Dimensions, height x width x depth (mm)720 x 250 x 660Weight (kg)104 (68 w/o battery)128 (88 w/o battery)

 Technology

 UPS-IND HF

1206

1210

Conversion TypeOn-line double conversion (online)RectifierIGBT TechnologyInverterPWM Technology with IGBT conmuted at 19.2 kHzInverter ConfigurationH BridgeInverter TypePulse width modulated (PWM)Battery StatusReal time Online/Discharge information with 3% precisionThermal Dissipation (kBTU/h)1.83CertificationsCE-IEC 62040 – 1, ISO 9001 : 2015, NOM-001-SCFT-1993Communication InterfaceRS-232 + SNMP (EPO Dry contacts, USB, optional)Monitor ScreenLCD screen indicates UPS operating statusAlarmirregular power supply, low battery voltage &amp; UPS malfunction

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)