---
title: "SPV-IND 3000 Three Phase"
url: "https://grupoindustronic.com/en/product/spv-ind-3000-three-phase/"
date: "2020-04-29"
modified: "2026-02-23"
type: "producto"
lang: "en"
---

SPV-IND 3000: Industrial three-phase surge protector                                       [](#)

 # SPV-IND 3000 Three Phase

###### Surge Protection

  ![](https://grupoindustronic.com/wp-content/uploads/2020/01/SPV-IND-3100.png)

  ![](https://grupoindustronic.com/wp-content/uploads/2020/01/SPV-IND-3100.png)

 ## SPV-IND 3000 Three Phase

###### Surge Protection

  [ ![Amazon](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/logo-amazon.png) ](https://www.amazon.com.mx/stores/Industronic/page/A9B999EB-18DA-411C-B8A4-C1453C952E10?ref_=ast_bln) [ ![Mercado libre](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/logo-mercadolibre.png) ](https://listado.mercadolibre.com.mx/pagina/grupoindustronic/)

 ###### 50 ~ 530 kA

 Capacity

  10 Year Warranty

Manufactured in Mexico

 Industrial grade protection from dangerous voltage spikes, electrical noise and power line disturbances. Industrial grade design and materials ensure safe and reliable operation for demanding applications.

- High frequency noise filter
- Commercial Grade Cabinet
- Immediate Response Time
- Derived Parallel Connection
- TMOV Technology
- Parallelable Technology

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ SPV-IND 3000 Datasheet ](https://grupoindustronic.com/wp-content/uploads/2021/06/25-Datasheet-SPV-IND-3000-.pdf)

##   ![Garantías](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Warranties

- [ SPV-IND Warranty ](https://industronicservice.zendesk.com/hc/es-419/articles/36885868773907-SPV-IND-Warranty)

 Share: [Correo](mailto:?subject=SPV-IND%203000%20Three%20Phase&body=https://grupoindustronic.com/en/product/spv-ind-3000-three-phase/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/spv-ind-3000-three-phase/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/spv-ind-3000-three-phase/)

 #### Designed with Durable &amp; Resistant Materials

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/gabinete-contra-intemperie.png)

###### Commercial Grade Cabinet

Steel NEMA 4, IP 65 grade cabinets offer robust, resilient and long lasting performance.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/actua-en-nano-segundos.png)

###### Immediate Response Time

Voltage spikes are corrected in nanoseconds, ensuring long life and protection of the load.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/tecnologia-tmov.png)

###### MOV Technology

Metal oxide varistors protect from voltage spikes and over voltage on the line.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/filtraje-de-ruidos.png)

###### High frequency noise filter

Allows for precise data transfer and correct measurement during signaling such as in a radar transmission or heart-rate monitor.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/conexion-en-paralelo.png)

###### Derived Parallel Connection

Secures safe &amp; continuous operation in the presence of voltage transients or electrical noise.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/caracteristicas-amcr9.png)

###### Parallelable Technology

Easily increase the total capacity of the SPV to adapt to the load.

### Video

#### Applications

 ![Audio Visual Recording Equipment](https://grupoindustronic.com/wp-content/uploads/2020/02/estudios-de-grabacion-de-audio-y-video.png)

###### Audio Visual Recording Equipment

Protects cameras, mixers and recorders from power surges and electrical fluctuations.

 ![Communication Center](https://grupoindustronic.com/wp-content/uploads/2020/02/centro-de-comunicaciones.png)

###### Communication Center

Ensure the operation of servers and telecommunications equipment during power failures.

 ![Data Centers](https://grupoindustronic.com/wp-content/uploads/2020/02/centros-de-datos_data-center.png)

###### Data Centers

Ensure continuity and stability in servers and critical storage systems.

 ![Load Center](https://grupoindustronic.com/wp-content/uploads/2020/02/tableros-principales.png)

###### Load Center

Protection of electrical distribution panels against voltage spikes and power fluctuations.

 ![Main Electric Panel Switch](https://grupoindustronic.com/wp-content/uploads/2020/04/APPS3.png)

###### Main Electric Panel Switch

Protect main electrical panels from surges and frequency variations.

 ![Sensitive Loads](https://grupoindustronic.com/wp-content/uploads/2020/02/servidores-1.png)

###### Sensitive Loads

Protect medical devices and sensitive equipment from electrical variations and transients.

 ![UPS Uninterruptible Power Supply and Voltage Regulators](https://grupoindustronic.com/wp-content/uploads/2020/02/sistemas-de-energia.png)

###### UPS Uninterruptible Power Supply and Voltage Regulators

Ensure additional protection against voltage spikes for your UPS equipment and voltage regulators.

  &gt;

 &lt;

#### Technical Specifications

 SPV IND 3000 (127/220 V)

The following are the technical specifications of the SPV IND 3000 for 127/220 V.

 Electrical

 Model SPV-IND

50

100

200

400

Nominal Voltage (V)110/190, 120/208, 127/220Phases3ConfigurationStar: 3 Phases, Neutral y GroundProtection Voltage (VPR)700 V (P-N), 700 V (P-G), 700 V (N-G), 1400 V (P-P)&gt;Maximum Current Operation Voltage (MCOV))150 V (P-N, N-G, P-G)Type / Recommended application classType 1 &amp; Type 2Short Circuit Current Capacity (SCCR)200kANominal Discharge Current (In)20kAProtection current per phase (kA)264080150Three-Phase protection current (kA)50100200400Frequency (Hz)50/60Energy capacity (J)640128025604960Modos de protección10 modes P1-N, P1-G, P2-N, P2-G, P3-N, P3-G, N-G, P1-L2, P2-P3, P1-PL3EMI / RFI FilteringUp to 50 dB at 10 kHz to 100 MHz

 Mechanical

 Model SPV-IND

50

100

200

400

CabinetNEMA 4, IP 65, 16 caliber galvanized steel with baked epoxy coating in blackDimensions, height x width x depth (mm)260 x 210 x 90Weight (kgs)2.3 2.42.6Connection type 5 flexible cables AWG 10 5 flexible cables AWG 8

 Physical

 Model SPV-IND

50

100

200

400

Maximum operating altitude (mamsl)5,000Operating temperature (°C)-40 ~ 70LED indicator activation time&lt; 1 secRelative humidityfrom 5% to 95% without condensation

 Applicable characteristics

 Model SPV-IND

50

100

200

400

Average efficiency100%Harmonic distorsionDoes NOT add harmonic distortion to the lineAnti-ignition systemThermostable polymer encapsulated varistors &amp; smoke proof sealed metal cabinetLED IndicatorPhase failure, phase loss &amp; current between neutral and groundRemote monitoringDry contact signal (NA, NC, COM)/td&gt;Audible indicatorIn case of failure or phase lossSuggested switch type3 poles, 30 A, 250 VcaCertificationsComplies with: NOM, UL 1449 3rd Edition; components comply to UL94V-0

 SPV IND 3000 (277 / 480)

The following are the technical specifications of the SPV IND 3000 for 227/480 V.

 Electrical

 100

200

400

530

Nominal Voltage (V)254 / 440, 266 / 460, 277 / 480Phases3ConfigurationStar: 3 Phases, Neutral y GroundProtection Voltage (VPR)1200 V (P-N), 1200 V (P-G), 1200 V (N-G), 2400 V (P-P)&gt;Maximum Current Operation Voltage (MCOV))385 V (P-N, N-G, P-G)Type / Recommended application classType 1 &amp; Type 2Short Circuit Current Capacity (SCCR)200kANominal Discharge Current (In)20kAProtection current per phase (kA)4080150300Three-Phase protection current (kA)100200400530Frequency (Hz)50/60Energy capacity (J)19553910773510030Modos de protección10 modes P1-N, P1-G, P2-N, P2-G, P3-N, P3-G, N-G, P1-L2, P2-P3, P1-PL3EMI / RFI FilteringUp to 50 dB at 10 kHz to 100 MHz

 Mechanical

 100

200

400

530

CabinetNEMA 4, IP 65, 16 caliber galvanized steel with baked epoxy coating in blackDimensions, height x width x depth (mm)260 x 210 x 90Weight (kgs) 2.42.62.7Connection type 5 flexible cables AWG 10 5 flexible cables AWG 8

 Physical

 100

200

400

530

Maximum operating altitude (mamsl)5,000Operating temperature (°C)-40 ~ 70LED indicator activation time&lt; 1 secRelative humidityfrom 5% to 95% without condensation

 Applicable characteristics

 100

200

400

530

Average efficiency100%Harmonic distorsionDoes NOT add harmonic distortion to the lineAnti-ignition systemThermostable polymer encapsulated varistors &amp; smoke proof sealed metal cabinetLED IndicatorPhase failure, phase loss &amp; current between neutral and groundRemote monitoringDry contact signal (NA, NC, COM)/td&gt;Audible indicatorIn case of failure or phase lossSuggested switch type3 poles, 30 A, 600 VcaCertificationsComplies with: NOM, UL 1449 3rd Edition; components comply to UL94V-0

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)