 # FAPA-IND 53000

###### Harmonic Filter

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 ## FAPA-IND 53000

###### Harmonic Filter

  ###### 50~1000 kVA

 Capacity

  2 Year Warranty

Manufactured in Mexico

 The FAPA-IND Adaptive Harmonic Filter is designed to reduce harmonic current distortion at 5% full load and 8% to 30% load. It is compliant with Grid Code 2.0 and IEEE 519, in addition to improving the service life and prolonging the connected loads, as well as improving the Power Factor.

- Impedance 5%.
- Designed to work in 2 or 3 phases.
- Supports overload of up to 200% for 3 minutes
- Built in harmonic distortion meter
- Effective filtering from 50% of the load onward

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ Datasheet FAPA-IND 5300 (50-150 kVA) ](https://industronicservice.zendesk.com/hc/es-419/articles/18658411295379-Ficha-T%C3%A9cnica-FAPA-IND-5300-50-150-kVA-)
- [ Datasheet FAPA-IND 5300 (100-1000 kVA) ](https://industronicservice.zendesk.com/hc/es-419/articles/18658397354387-Ficha-T%C3%A9cnica-FAPA-IND-5300-100-1000-kVA-)

 Share: [Correo](mailto:?subject=FAPA-IND%2053000&body=https://grupoindustronic.com/en/product/fapa-ind-53000/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/fapa-ind-53000/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/fapa-ind-53000/)

  ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2022/07/5.png)

###### Impedance 5%

Mains short-circuit resistance of 5%.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2022/07/Iconos-Filtro-de-armonicas2.png)

###### Phase Adjustment

Designed to work in 2 or 3 phases, depending on the required connection.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2022/07/Iconos-Filtro-de-armonicas.png)

###### Overload protection

Protection against overloads that can cause severe damage to equipment or machinery.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2022/07/icono-medidor-de-distorsion-armonica-2.png)

###### Harmonic distortion meter

The FAPA-IND 5300 has an integrated harmonic distortion meter.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2023/08/Icono-FAPA-delta-estrella-e1691011444761.png)

###### Delta or star configuration

Allows delta or star configuration in three-phase connections, for greater control.

#### Applications

 ![Automated Assembly Lines](https://grupoindustronic.com/wp-content/uploads/2020/04/linea-autom-1.png)

###### Automated Assembly Lines

Maintain continuous operation of automated production lines during power failures.

 ![CNC Machinery](https://grupoindustronic.com/wp-content/uploads/2020/04/cnc.png)

###### CNC Machinery

Ensure accuracy of CNC machinery against electrical fluctuations and frequency variations.

 ![Computer Rooms](https://grupoindustronic.com/wp-content/uploads/2020/02/computadoras.png)

###### Computer Rooms

Protect servers and network equipment against electrical fluctuations and power surges.

 ![Data Centers](https://grupoindustronic.com/wp-content/uploads/2020/02/centros-de-datos_data-center.png)

###### Data Centers

Ensure continuity and stability in servers and critical storage systems.

 ![Heavy Industry](https://grupoindustronic.com/wp-content/uploads/2020/02/industria-pesada.png)

###### Heavy Industry

Protect high power equipment against overloads and frequency variations.

 ![IT Servers](https://grupoindustronic.com/wp-content/uploads/2020/02/servidores-1.png)

###### IT Servers

Protect servers and network equipment against power fluctuations and voltage drops.

 ![Lab equipment](https://grupoindustronic.com/wp-content/uploads/2020/04/eq-analisis.png)

###### Lab equipment

Ensure the accuracy of laboratory equipment by protecting it from electrical variations.

 ![Machinery](https://grupoindustronic.com/wp-content/uploads/2020/04/maquinaria.png)

###### Machinery

Protect industrial machinery from power surges and voltage drops.

 ![Robotics](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-robotica.png)

###### Robotics

Maintain the accuracy of robotic systems during power fluctuations and power surges.

 ![UPS Uninterruptible Power Supply and Voltage Regulators](https://grupoindustronic.com/wp-content/uploads/2020/02/sistemas-de-energia.png)

###### UPS Uninterruptible Power Supply and Voltage Regulators

Ensure additional protection against voltage spikes for your UPS equipment and voltage regulators.

 ![Water pumping systems](https://grupoindustronic.com/wp-content/uploads/2020/04/APPS-3.png)

###### Water pumping systems

Ensure continuous operation of water pumps during power failures and frequency variations.

  &gt;

 &lt;

#### Technical Specifications

 Filter parameters

 **FAPA-IND Model****53100****53150****53200****53300****53500****53800****531000**Capacity(kVA)1001502003005008001000Voltages (VAC) L-L440/460/480Phases3 phases / 2 phasesFrequency (Hz)50-60 HzUsage (W)1035134015141932250942064400Max. constant current AmpCharacteristic impedance5%Characteristic impedance95% @ 110% charge / 80% @ 150% chargeOverload150% to 1 minute maximumEfficiency99.0%99.2%99.2%99.4%99.5%99.5%99.6%Reduction of current harmonic distortionTHDi% 8% at 30% load, THDi% 5% at full loadMaximum recommended voltage unbalance±1%Filter typeReject reactor with delta capacitors

 Power meter

 Power meter**53100****53150****53200****53300****53500****53800****531000**Active power, apparent power, energy, current and power factorClass 0.5 (0.5% error)Reactive powerClass 1 (1% error)Voltage and frequencyClass 0.2 (0.2% error)THDv – THDiClass 1 (odd 1-31) (1% error)International meter standardsAccording to: IEC – CE – UE – RoHS

 Physical

 Physical**53100****53150****53200****53300****53500****53800****531000**Dimensions HxWxD (mm)1300 x 750 x 6502000 x 1000 x 800Weight (kg)180210230300500650700Temperature ranges-10°C to +40°CRelative humidityFrom or up to 95% without condensationCabinetSteel with baked-on electrostatic epoxy coatingMaximum operating altitude (m.a.s.l.)2000 meters above sea level

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)