title: "AMCR 2300 GEN 3"
url: "https://grupoindustronic.com/en/product/amcr-2300-gen-3-5/"
date: "2020-04-24"
modified: "2024-12-30"
type: "producto"
lang: "en"
---

Power Conditioner | AMCR 2300 | Grupo Industronic                                       [](#)

 # AMCR 2300 GEN 3

###### Power Conditioners

  ![2300 - 250 ~ 1500](https://grupoindustronic.com/wp-content/uploads/2020/01/AMCR-G3-2300-250-1500-kVA-1.png)

 ![AMCR G3 2300 display](https://grupoindustronic.com/wp-content/uploads/2020/01/pntalla-amcr.png)

 ![AMCR 2300 bypass](https://grupoindustronic.com/wp-content/uploads/2020/04/bypass-amcr.png)

 ![Conexiones AMCR G3 2300](https://grupoindustronic.com/wp-content/uploads/2020/01/1ups-6-10-conexion-close-up-1.png)

  ![](https://grupoindustronic.com/wp-content/uploads/2020/01/AMCR-G3-2300-250-1500-kVA-1.png)

 ![](https://grupoindustronic.com/wp-content/uploads/2020/01/pntalla-amcr.png)

 ![](https://grupoindustronic.com/wp-content/uploads/2020/04/bypass-amcr.png)

 ![](https://grupoindustronic.com/wp-content/uploads/2020/01/1ups-6-10-conexion-close-up-1.png)

 ## AMCR 2300 GEN 3

###### Power Conditioners

  ###### 300 ~ 1000 kVA

 Capacity

###### +/-2%

 Voltage regulation

  10 Year Warranty

Manufactured in Mexico

 Industrial grade performance, top tier precision.
Redundancy and 100% reliability.

- Overload Protection
- Spike Supressor
- Automatic Shut Off
- 99% Efficiency
- Event History
- Voltage Correction
- Remote Monitoring
- Maintenance Bypass
- Digital Display Panel

  [ Request quote ](#cotizacion)

 ##   ![Fichas Técnicas](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Technical Data Sheets

- [ AMCR G3 2300 300 ~ 500 kVA Datasheet ](https://grupoindustronic.com/wp-content/uploads/2020/04/10-Datasheet-AMCR-G3-2300-300-500-2.pdf)
- [ AMCR G3 2300 800 ~ 1000 kVA Datasheet ](https://grupoindustronic.com/wp-content/uploads/2020/04/11-Datasheet-AMCR-G3-2300-800-1000-2.pdf)

##   ![Garantías](https://grupoindustronic.com/wp-content/themes/industronic-theme/img/icono-manual.svg) Warranties

- [ AMCR Warranty ](https://industronicservice.zendesk.com/hc/es-419/articles/36884580248339-AMCR-Warranty)

 Share: [Correo](mailto:?subject=AMCR%202300%20GEN%203&body=https://grupoindustronic.com/en/product/amcr-2300-gen-3-5/) [Facebook](https://www.facebook.com/sharer/sharer.php?u=https://grupoindustronic.com/en/product/amcr-2300-gen-3-5/) [LinkedIn](https://www.linkedin.com/shareArticle?mini=true&url=https://grupoindustronic.com/en/product/amcr-2300-gen-3-5/)

 #### Guaranteed protection for your devices and electronic equipment

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/caracteristicas-amcr10.png)

######  Overload Protection

Protects against stress, overheating &amp; damage due to voltage overloads of up to 400%, such as in motors, compressors or pumps with inherent fluctuating energy demands.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/caracteristicas-amcr7.png)

###### Spike Supressor

Also known as a surge suppressor, protects against aggressive transient voltage spikes that can permanently damage electronic components, cause overheating and significantly reduce lifespan of equipment connected directly to the power line.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/caracteristicas-amcr13.png)

###### Automatic Shut Off

Performs automatic shut off for the input to protect the load against dangerous voltage variations. When the voltage level comes down to safe levels, the unit reestablishes connection and operates normally.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/caracteristicas-amcr11.png)

###### 99% Efficiency

Highly efficient operation allows for low cost operation and supports product longevity.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/caracteristicas-amcr5.png)

###### Event History

Integrated Energy Monitor allows easy visual access to updated electrical data that can greatly improve fact based decision making for changes and improvements in energy consumption as well as detect areas of opportunity for preventing faulty practices.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/actua-en-nano-segundos.png)

###### Voltage Correction

Instantaneous 8 millisecond voltage correction factor protects data and processing integrity.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/caracteristicas-amcr3.png)

###### Remote Monitoring

Convenient and timely information is consistently available. Ideal for off site locations

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/03/caracteristicas-amcr9.png)

###### Maintenance Bypass

Bypass switch protects the load, allowing continuous power even in case of maintenance or repair.

 ![Icono rayo](https://grupoindustronic.com/wp-content/uploads/2020/01/amcr-negro4.png)

###### Digital Display Panel

Real time, user friendly digital screen, allows easy interaction with the equipment and displays useful information for quick response times to possible dangerous electrical situations as well as providing the ability for taking immediate preventive actions.

#### Applications

 ![Audiovisual Systems](https://grupoindustronic.com/wp-content/uploads/2020/04/audiovisual.png)

###### Audiovisual Systems

Ensure the operability of audiovisual equipment against electrical fluctuations.

 ![Automated Assembly Lines](https://grupoindustronic.com/wp-content/uploads/2020/04/linea-autom-1.png)

###### Automated Assembly Lines

Maintain continuous operation of automated production lines during power failures.

 ![CNC Machinery](https://grupoindustronic.com/wp-content/uploads/2020/04/cnc.png)

###### CNC Machinery

Ensure accuracy of CNC machinery against electrical fluctuations and frequency variations.

 ![Computer equipment](https://grupoindustronic.com/wp-content/uploads/2020/02/computadoras.png)

###### Computer equipment

Protect computers and peripherals against power surges and surges.

 ![Lighting Systems](https://grupoindustronic.com/wp-content/uploads/2020/02/sistemas-de-iluminacion.png)

###### Lighting Systems

Maintain stable lighting in critical environments against voltage drops.

 ![Medical Equipment](https://grupoindustronic.com/wp-content/uploads/2020/04/hospital.png)

###### Medical Equipment

Prevent failure of critical medical equipment during power outages and surges.

 ![Robotics](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-robotica.png)

###### Robotics

Maintain the accuracy of robotic systems during power fluctuations and power surges.

 ![Telecommunication](https://grupoindustronic.com/wp-content/uploads/2020/02/icono-equipo-de-telecomunicacion.png)

###### Telecommunication

Ensure the continuity of telecommunications services in the event of power surges.

  &gt;

 &lt;

#### Technical Specifications

 AMCR G3 2300 300 ~ 500 kVA

 Input

 AMCR

23300

23400

23500

Capacity (kVA / kW)300/300400/400500/500Input Voltage (V)110/190, 115/200, 120/208, 127/220 or 254/440, 266/460, 277/480Overload ProtectionThermo-magnetic switchRange (Accepted)± 15%Operational Frequency60 ± 10%, does not alter frequency\*Harmonic DistortionLess than 2 % THDPower FactorDoes NOT alter, adaptable to load requirement\* Tolerance available under evaluation of the Engineering department

 Output

 AMCR

23300

23400

23500

Voltage Regulation Range± 2% (typical)Output Voltage (V)110/190, 115/200, 120/208, 127/220 or 254/440, 266/460, 277/480Power Supply ImpedanceLess than 2%Sustained High/Low Voltage ProtectionContactor or relay on the output, automatic shut off (varies by model)Correction TimeImmediate, (8.3 milliseconds, 1/2 cycle)ResetAutomatic (programmed at factory)Reset Time3 second standard time \*\*\*\* Factory configurable on request

 Physical &amp; Mechanical

 AMCR

23300

23400

23500

Recommended UseDomestic, commercial and/or industrial, non vibratory, indoor useTransformersElectrolytic copper magnetic wire and silicon steel sheetCooling &amp; VentilationNatural convectionCabinetGalvanized steel sheet with tubular steel framePaint FinishPrimer and electrostatic baked epoxy powder coating or air-dry (varies by model)Maximum Altitude Of Operation (mamsl)3,000Operational Temperature (°C)0 ~ 40Relative Humidity0 ~ 95% without condensationDimensions, height x width x depth (mm)1575 x 1570 x 8022360 x 2290 x 1330Weight (kg)89210521672

 Technology

 AMCR

23300

23400

23500

High Frequency Noise ProtectionPI FilterControl TechnologyMicrocontrollerMonitoring (Operational Status)Display with LEDs / Ethernet (optional)Measurement ParametersVoltage, current, power, frequency, power factorElectronic CommutationTRIACs or SCRs (varies by model)

 Electrical

 AMCR

23300

23400

23500

RegulationLine-Line &amp; Line-NeutralSpike SuppressorVaristors on the outputEfficiency98% minimumOverload CapacityUp to 400% in intermittent startups

 AMCR G3 2300 800 ~ 1000 kVA

 Input

 AMCR

23800

231000

Capacity (kVA / kW)800/8001000/1000Input Voltage (V)110/190, 115/200, 120/208, 127/220 or 254/440, 266/460, 277/480Overload ProtectionThermo-magnetic switchRange (Accepted)± 15%Operational Frequency60 ± 10%, does not alter frequency\*Harmonic DistortionLess than 2 % THDPower FactorDoes NOT alter, adaptable to load requirement\* Tolerance available under evaluation of the Engineering department

 Output

 AMCR

23800

231000

Voltage Regulation Range± 2% (typical)Output Voltage (V)110/190, 115/200, 120/208, 127/220 or 254/440, 266/460, 277/480Power Supply ImpedanceLess than 2%Sustained High/Low Voltage ProtectionContactor or relay on the output, automatic shut off (varies by model)Correction TimeImmediate, (8.3 milliseconds, 1/2 cycle)ResetAutomatic (programmed at factory)Reset Time3 second standard time \*\*\*\* Factory configurable on request

 Physical &amp; Mechanical

 AMCR

23800

231000

Recommended UseDomestic, commercial and/or industrial, non vibratory, indoor useTransformersElectrolytic copper magnetic wire and silicon steel sheetCooling &amp; VentilationNatural convectionCabinetGalvanized steel sheet with tubular steel framePaint FinishPrimer and electrostatic baked epoxy powder coating or air-dry (varies by model)Maximum Altitude Of Operation (mamsl)3,000Operational Temperature (°C)0 ~ 40Relative Humidity0 ~ 95% without condensationDimensions, height x width x depth (mm)2600 x 2500 x 1500Weight (kg)21003000

 Technology

 AMCR

23800

231000

High Frequency Noise ProtectionPI FilterControl TechnologyMicrocontrollerMonitoring (Operational Status)Display with LEDs / Ethernet (optional)Measurement ParametersVoltage, current, power, frequency, power factorElectronic CommutationTRIACs or SCRs (varies by model)

 Electrical

 AMCR

23800

231000

RegulationLine-Line &amp; Line-NeutralSpike SuppressorVaristors on the outputEfficiency98% minimumOverload CapacityUp to 400% in intermittent startups

 #### Request quote

#### Power Calculator

 Instantly calculate equipment capacity by filling in the missing information:

  Calculate

#### Latest articles

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Data Center Infrastructure: Power, Backup, and Business Continuity](https://grupoindustronic.com/en/data-center-infrastructure-power-backup-and-business-continuity/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Smart Energy Management: Efficiency and Electrical Control](https://grupoindustronic.com/en/smart-energy-management/)

 [Energy](https://grupoindustronic.com/en/category/energy/)

 [Sustainable Companies in Mexico and Their Impact on the Energy Sector](https://grupoindustronic.com/en/sustainable-companies-in-mexico/)

 [See all](https://grupoindustronic.com/en/blog/)